Draft Inducer Motor, 1 stage. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Inducer blower motor, three phase.The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Draft inducer motor, one stage with shaded pole motor *Note: All models use this part with the exception of: *UX/DX100A, UX/DX100C, UX/DX1C100, UX1D100, UX/DX120A, UX/DX120C. These select models use item 2458691.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Draft inducer motor, one stage, ball bearing.The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Blower; inducer-80-1.200-psc

Blower; inducer-80-2.15-psc

Blower; inducer-80-1.800-psc

Blower; inducer-80-1.75-psc

Blower; inducer-80-1.40-psc

Blower; inducer-80-0.900-sp, c.0
The draft inducer motor is the first part to fire in every Trane heating cycle. It pulls combustion gases safely out of the heat exchanger and vents them through the flue before the igniter even sparks. When the inducer fails, you'll hear rattling or grinding, or the furnace simply won't start. The pressure switch won't close because airflow isn't confirmed — and without that signal, the igniter never gets its command.
Trane inducer motors are engineered for precise air handling and pressure switch compatibility. An OEM replacement maintains the correct motor speed (RPM), flange fit, and mounting orientation that Trane's control board expects. Aftermarket inducers often cause nuisance pressure-switch errors or run too slowly to pull adequate draft.
Enter your Trane model number above to find the exact inducer motor assembly for your furnace — Trane's XC95m, XR95, XR80, and XV80 models each use different motor specs. OEM Trane inducers ship with gaskets and mounting hardware included.
The clearest sign is a furnace that won't start or shuts off within seconds of ignition. You may also hear rattling, grinding, or loud humming from the furnace when the blower tries to cycle. A failed inducer motor prevents the pressure switch from closing, so the control board never signals the igniter to spark. Check for loose wiring first — if connections are tight and the motor still won't run, test the capacitor with a multimeter before replacing the entire motor assembly. Trane inducers are sealed units, so internal bearing failure means replacement, not repair.
Trane furnace inducers are sealed assemblies — motor, wheel, and housing are permanently bonded. You'll need to replace the entire inducer motor assembly; individual motor replacement is not an option. When you order an OEM Trane inducer, it comes with the gasket and mounting hardware, so you have everything needed for installation. Some contractors keep a spare inducer assembly on the truck because it's one of Trane's highest-failure points in cold-weather regions.
OEM Trane inducers are engineered to deliver exact airflow rates and pressure signatures that match Trane's IFC control board and pressure switch calibration. Aftermarket motors often have slightly different RPM specs or impeller designs, which can cause false pressure-switch errors even if the motor itself works. You'll spend more on a Trane OEM inducer, but you avoid costly callbacks and customer frustration. Trane's factory-certified positioning means owners expect reliability — OEM parts deliver it.
Use your furnace model number to get the exact inducer assembly. Trane XC95m, XR95, and XR80 models use different inducers — even slight model variations affect motor specifications. Look at your furnace nameplate for the full model number (typically found inside the blower compartment or on the cabinet), then search Trane furnace inducer parts by model to confirm compatibility before ordering. Our model lookup tool cross-references your furnace to the correct inducer assembly with part numbers and wiring diagrams.


Enjoy the convenience of ordering Trane Furnace Draft Inducer Motor parts online with Repair Clinic. We offer a No-Hassle 365-Day Return Policy, allowing you to return uninstalled parts for any reason within a year of purchase. Additionally, our Price Match Guarantee ensures you never overpay for genuine OEM replacement parts. With easy lookup by model or part number, finding the right part for your furnace is simple. Order by 9 p.m. For same-day shipping, ensuring your repairs are completed promptly. Trust Repair Clinic for reliable Trane furnace parts and support from Repair Clinic's online repair library provides the videos, guides, and diagrams you need for the repair. Shop now and keep your furnace running efficiently with confidence.
Trane prints the model number on the furnace nameplate, usually inside the blower compartment door or on the cabinet near the gas valve. Turn off power to the furnace, open the appropriate access panel, and copy the complete model number, including every letter and number. Then type it into the model number search to pull up the parts matched to your unit. Your furnace model number filters Repair Clinic's full Trane parts catalog, so you can narrow the selection to parts designed for that exact furnace rather than relying on appearance alone. Taking a moment to record the full number helps prevent compatibility mistakes and makes it easier to order with confidence knowing the fit is right.

Repair Clinic's online repair library gives you the tools to diagnose and fix your Trane Furnace without a service call. Common-symptom articles cover the most likely causes, part testing videos confirm the failed component, and step-by-step written guides walk you through the installation. Use the model number lookup to confirm the exact OEM part, and exploded-view diagrams and wiring illustrations support the more involved jobs.

A furnace that fails to ignite can leave your home in the cold. Common issues include a faulty igniter, malfunctioning flame sensor, or a defective draft inducer fan motor. Replacing furnace filters and cleaning furnace parts can help prevent these problems.

A malfunctioning furnace blower fan motor can disrupt your heating system, but replacing it doesn't have to be daunting. This article explains the blower motor's role in circulating air through your home and provides detailed, step-by-step guidance for safely removing and installing a new furnace blower fan motor.

A gas furnace that starts and then stops unexpectedly can be frustrating, especially during cold weather. This article explains five common causes, including issues with the flame sensor, pressure switch, control board, draft inducer fan motor, or air flow. Learn how each cause may impact your furnace's operation and get tips to resolve the problem.