Keep air moving with this genuine OEM fan motor, part number 92W51, designed for select GE or Lennox Air Conditioner, Packaged Unit/RTU, Heat Pump, or Central Air Conditioners.
Grid is 1 inch square
  Fan Motor 92W51
  Fan Motor 92W51
  Fan Motor 92W51
Manufacturer Part

Fan Motor 92W51

Genuine OEM Part # 92W51RC Item # 2346898Alternative Part Number(s)
Manufacturer Part
Keep air moving with this genuine OEM fan motor, part number 92W51, designed for select GE or Lennox Air Conditioner, Packaged Unit/RTU, Heat Pump, or Central Air Conditioners.
Grid is 1 inch square
  Fan Motor 92W51
  Fan Motor 92W51
  Fan Motor 92W51
$206.25
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Keep air moving with this genuine OEM fan motor, part number 92W51, designed for select GE or Lennox Air Conditioner, Packaged Unit/RTU, Heat Pump, or Central Air Conditioners.
Loading stock status
$206.25
start a live chat with Repair Clinic customer support

This part 92W51 is compatible with:

Product Type:
Air Conditioner, Central Air Conditioner
Brands:
GE, Lennox

Related Articles & Videos

03:57
Troubleshooting
Air Conditioner Fan Not Working — Air Conditioner Troubleshooting
02:01
Troubleshooting
Air Conditioner Loud or Noisy — Air Conditioner Troubleshooting
01:47
Troubleshooting
Central Air Conditioner Is Noisy — Central Air Conditioner Troubleshooting
03:52
Troubleshooting
Air Conditioner Not Cooling — Air Conditioner Troubleshooting
03:58
Troubleshooting
Air Conditioner Compressor Won't Run — Air Conditioner Troubleshooting
Frequently Bought with Fan Motor
P291-4554RS Dual Run Capacitor
W10311524 Air Filter
LA660003 Fan Blade
WP694089 Blower Wheel

Fan Motor Customer Reviews

Common Problems Fixed by the Fan Motor

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Air conditioner fan not working

Very Likely

Heat pump is noisy or loud

Likely

Air conditioner is loud or noisy

Likely

Central air conditioner is noisy or loud

Likely

Heat pump not cooling

Likely

Heat pump not heating

Likely

Heat pump won't turn on

Likely

Heat pump fan motor does not run

Likely

Heat pump is frequently cycling/short cycling

Likely

Air conditioner coils freezing

Likely

Central Air Conditioner Condenser fan motor does not run

Likely

Central Air Conditioner Condensing unit does not run

Likely

Heat pump coils frosting up

Likely

Central air conditioner circuit breaker keeps tripping

Likely

Heat pump circuit breaker keeps tripping

Possible

Air conditioner not blowing enough

Possible

Air conditioner not cooling

About the Fan Motor

Try turning the blade by hand. If the blade does not turn freely, this indicates that the motor bearings are worn out. If the motor bearings are worn out, replace the motor. If the blade turns freely, test the incoming power to the fan motor. If power is getting to the fan motor, but the motor won’t run, this also indicates that the motor is defective and should be replaced.

Alternative Part Number(s)

Replaces Part Number 98M36
Replaces Part Number 100483-27
Replaces Part Number 100483-33
Replaces Part Number 63W25
Replaces Part Number 100483-11
Replaces Part Number 92W51
Replaces Part Number 11X75
Replaces Part Number 100483-42