Right driving box sub-assy
Grid is 1 inch square
Heat Pump Motor 2011220001
Heat Pump Motor 2011220001
Manufacturer Part

Heat Pump Motor 2011220001

Genuine OEM Part # 2011220001RC Item # 4386297
Manufacturer Part
Right driving box sub-assy
Grid is 1 inch square
Heat Pump Motor 2011220001
Heat Pump Motor 2011220001
$68.35
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Right driving box sub-assy
Loading stock status
$68.35
start a live chat with Repair Clinic customer support

This part 2011220001 is compatible with:

Product Type:
Heat Pump
Brands:
Bryant, Carrier

Motor Customer Reviews

Common Problems Fixed by the Motor

Based on customer reports and repair data, this part commonly fixes these issues:

Likely

Heat pump not cooling

Likely

Heat pump not heating

About the Motor

Since the circulation blower fan motor is the component that circulates the cooled air through the home's venting, a defective motor will result in the unit not cooling. You can use a multimeter to test the motor for electrical continuity, a continuous electrical path present in the motor, as well as determine if power is reaching the motor. You can also try turning the blower wheel by hand. If the wheel does not turn freely, it's likely the motor bearings have seized and the motor will need to be replaced.