Shop replacement repair parts for Whirlpool Dryer model LG7801XSW2

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer gas burner valve solenoid set. If the dryer does not heat or heats intermittently the coils could be defective. To test, watch the burner and if the igniter glows for a while and then shuts off without the gas igniting, it usually means one of these coils is bad.

Dryer drum drive motor with pulley

The Whirlpool Burner Igniter Kit 279311 is a high-quality replacement part that ignites gas to light the dryer burner. It replaces multiple igniters and requires safety precautions and disconnection from utilities before installation.

Gas dryer sensor for igniter and flame. The sensor is located across from the gas igniter at the dryer’s burner assembly. This flame sensor should be closed for continuity at room temperature. Check for continuity with a multi-meter before replacing.

Adjustable dryer cycling thermostat kit L135-155. The cycling thermostat cycles the heat on and off to regulate the air temperature. If the cycling thermostat is defective, the dryer will not heat. To determine if the thermostat is defective, use a multimeter to test it for continuity.

Gas valve assembly with two & three terminal coils

Harness, wiring

Wire harness, gas valve

Thermal cut-out (fuse)

Harness, wiring

Harness, wiring

Timer for dryer

Harness, wiring

Replacement gas burner and igniter kit