Shop replacement repair parts for Trane Central Air Conditioner model 2TTB0030A1000AA

Drier; filter,suction line, c306sthh, 3/4 odf

Cover; controls, 16.18 x 11.19
Maintain your 2TTB0030A1000AA central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The 2TTB0030A1000AA is a two-and-a-half-ton, 13 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. Trane and American Standard are sister brands under the same parent company. The 2TTB0030 and 2TTB3030 are related production generations of the same two-and-a-half-ton XR13 platform. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Trane OEM parts for the 2TTB0030A1000AA including the Trane capacitor parts, Trane contactor parts, Trane fan motor parts, and Trane high-pressure switch parts. Browse the Trane central air conditioner parts catalog filtered by 2TTB0030A1000AA for the complete parts inventory.
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the 2TTB0030A1000AA. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
The 2TTB0030A1000AA is a two-and-a-half-ton, 13 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. Trane and American Standard are sister brands under the same parent company. The 2TTB0030 and 2TTB3030 are related production generations of the same two-and-a-half-ton XR13 platform.
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
The 2TTB0030A1000AA and 2TTB3030A1000AA are successive production generations of the same two-and-a-half-ton Trane XR13 platform. Most service components including the dual run capacitor are shared between both generations, but confirm the full designation before ordering a control board.
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic