Trane TUH1B060A9361AA Parts & Furnace Repair

Shop replacement repair parts for Trane Furnace model TUH1B060A9361AA

icons/furnace
Brand:Trane
Model:TUH1B060A9361AA
Product:Furnace
62 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SEN01114 Flame Sensor
$15.28

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SWT01635 Limit Switch
$20.69

Thermal limit switch, open at 180 degrees, close at 150 degrees

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
TRR01729 Transformer
$35.06

Transformer; 115v pri, 24v sec., 60hz, 35va, foot mount

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
KIT18110 Control Board
$448.17

Integrated single-stage furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
SWT02124 Flame Rollout Limit Switch
$12.35

Switch; switch-flame rollout, 82 degrees c, 180 deg

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
BAYLPKT210B Conversion Kit
$57.75

Natural Gas To LP Gas Conversion Kit. Kit includes, 7 orifice main burner #56, 1 LP spring conversion kit, 1 propane label, 1 conversion label, 1 conversion responsibility label, 1 installer's guide. *Should be installed by a certified Trane repairperson.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
BLW00864 Draft Inducer Motor
$401.68

Draft inducer motor, one stage with shaded pole motor *Note: All models use this part with the exception of: *UX/DX100A, UX/DX100C, UX/DX1C100, UX1D100, UX/DX120A, UX/DX120C. These select models use item 2458691.

Go

Trane TUH1B060A9361AA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Trane TUH1B060A9361AA problems ― and their solutions. Do any of these look familiar?
Furnace not heating
23 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
16 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Burner Tube
Limit Switch
Run Capacitor

Keep your Trane TUH1B060A9361AA furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The TUH1B060A9361AA is a 60,000 BTU, 80% AFUE upflow gas furnace from Trane, sharing its platform with the American Standard TUH1B060 as sister brands under Trane Technologies. At 60,000 BTU this is a mid-sized residential furnace with a moderate cycling rate that gives its igniter and inducer bearing reasonable service life compared to higher-output models. The furnace uses standard metal B-vent, produces no condensate, and has a straightforward 80% AFUE non-condensing service profile. Repair Clinic stocks genuine Trane OEM parts for the TUH1B060A9361AA including the Trane furnace igniter parts, Trane furnace flame sensor parts, and Trane furnace draft inducer motor parts. Browse the Trane furnace parts catalog filtered by TUH1B060A9361AA for the complete parts inventory.

TUH1B060A9361AA: Trane and American Standard Shared 60,000 BTU Upflow Platform

The Trane TUH1B060A9361AA and American Standard TUH1B060 are the same 80% AFUE upflow gas furnace platform under two sister brand names, with parts fully interchangeable between both designations. The TUH1B060A9361AA uses standard metal B-vent, produces no condensate, and has a single-speed inducer motor. The Trane furnace troubleshooting guide covers fault code blink patterns for the TUH1B platform control board.

Most Replaced Parts on the Trane TUH1B060A9361AA

Hot Surface Igniter for the TUH1B060A9361AA

Testing igniter resistance at room temperature with power off confirms or rules out failure in under two minutes. An infinite ohm reading means the element is open-circuit and must be replaced before any heating cycle can complete. The TUH1B060A9361AA igniter must heat to temperature within the control board timing window on every heating call.

Trane TUH1B060A9361AA Flame Sensor

The flame sensor passes a micro-amp signal through the burner flame to confirm sustained combustion after ignition. Annual cleaning with fine steel wool extends sensor service life on the TUH1B platform and prevents most early-season nuisance lockouts before the heating season begins.

Draft Inducer Motor for the TUH1B060A9361AA

The inducer is sized for 60,000 BTU combustion gas throughput and creates the negative pressure that opens the pressure switch to allow the ignition sequence to proceed. Bearing failure presents as grinding at startup during the pre-purge phase. An audible bearing should be scheduled for replacement before seizure causes a complete heating failure.

Trane TUH1B060A9361AA Control Board

Read and document the LED fault code before ordering any replacement. A board that produces the same fault code repeatedly after all identified components have tested good is a strong indicator that the board itself has failed.

Why Choose Repair Clinic for Trane TUH1B060A9361AA Parts

  • Genuine Trane OEM Components: Igniters, flame sensors, and inducers confirmed for the TUH1B060A9361AA 60,000 BTU upflow platform Trane furnace parts.
  • American Standard TUH1B060 Cross-Reference: Parts for the American Standard sister-brand equivalent are cross-referenced where interchangeable with the Trane TUH1B060A9361AA.
  • Fault Code Resources: Trane TUH1B LED blink code charts and wiring diagrams available alongside every part listing through Trane furnace troubleshooting.
  • 365-Day Returns: Return any uninstalled Trane part within a full year of purchase with no restocking fees.

Trane TUH1B060A9361AA Furnace Parts FAQ

What is the BTU output and efficiency of the Trane TUH1B060A9361AA?

The TUH1B060A9361AA is a 60,000 BTU input, 80% AFUE upflow gas furnace from Trane. The TUH designation identifies the upflow configuration and 060 identifies 60,000 BTU capacity on the TUH1B platform.

Is the Trane TUH1B060A9361AA the same as the American Standard TUH1B060?

Yes. American Standard is a sister brand to Trane under the Trane Technologies umbrella, and the TUH1B060A9361AA is the Trane-branded equivalent of the American Standard TUH1B060 on the same platform. Service components are interchangeable between both brand designations.

How do I read the fault code on the Trane TUH1B060A9361AA?

The control board LED on the TUH1B060A9361AA flashes a diagnostic blink code identifying the most recent fault. Count the flashes, note the pause, and match the pattern to the fault code chart on the sticker inside the blower compartment door.

Why does my TUH1B060A9361AA blower run continuously?

Continuous blower operation is usually caused by a thermostat fan switch set to ON rather than AUTO, a failed limit switch holding the blower relay closed, or a control board relay that has welded shut. Check the thermostat fan setting first before testing the limit switch and board.