Shop replacement repair parts for Trane Furnace model TUH1B060A9361AA

Blower; inducer draft, 1-stage

Adapter; flue connector with perforated air diffuse
Keep your Trane TUH1B060A9361AA furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The TUH1B060A9361AA is a 60,000 BTU, 80% AFUE upflow gas furnace from Trane, sharing its platform with the American Standard TUH1B060 as sister brands under Trane Technologies. At 60,000 BTU this is a mid-sized residential furnace with a moderate cycling rate that gives its igniter and inducer bearing reasonable service life compared to higher-output models. The furnace uses standard metal B-vent, produces no condensate, and has a straightforward 80% AFUE non-condensing service profile. Repair Clinic stocks genuine Trane OEM parts for the TUH1B060A9361AA including the Trane furnace igniter parts, Trane furnace flame sensor parts, and Trane furnace draft inducer motor parts. Browse the Trane furnace parts catalog filtered by TUH1B060A9361AA for the complete parts inventory.
The Trane TUH1B060A9361AA and American Standard TUH1B060 are the same 80% AFUE upflow gas furnace platform under two sister brand names, with parts fully interchangeable between both designations. The TUH1B060A9361AA uses standard metal B-vent, produces no condensate, and has a single-speed inducer motor. The Trane furnace troubleshooting guide covers fault code blink patterns for the TUH1B platform control board.
Testing igniter resistance at room temperature with power off confirms or rules out failure in under two minutes. An infinite ohm reading means the element is open-circuit and must be replaced before any heating cycle can complete. The TUH1B060A9361AA igniter must heat to temperature within the control board timing window on every heating call.
The flame sensor passes a micro-amp signal through the burner flame to confirm sustained combustion after ignition. Annual cleaning with fine steel wool extends sensor service life on the TUH1B platform and prevents most early-season nuisance lockouts before the heating season begins.
The inducer is sized for 60,000 BTU combustion gas throughput and creates the negative pressure that opens the pressure switch to allow the ignition sequence to proceed. Bearing failure presents as grinding at startup during the pre-purge phase. An audible bearing should be scheduled for replacement before seizure causes a complete heating failure.
Read and document the LED fault code before ordering any replacement. A board that produces the same fault code repeatedly after all identified components have tested good is a strong indicator that the board itself has failed.
The TUH1B060A9361AA is a 60,000 BTU input, 80% AFUE upflow gas furnace from Trane. The TUH designation identifies the upflow configuration and 060 identifies 60,000 BTU capacity on the TUH1B platform.
Yes. American Standard is a sister brand to Trane under the Trane Technologies umbrella, and the TUH1B060A9361AA is the Trane-branded equivalent of the American Standard TUH1B060 on the same platform. Service components are interchangeable between both brand designations.
The control board LED on the TUH1B060A9361AA flashes a diagnostic blink code identifying the most recent fault. Count the flashes, note the pause, and match the pattern to the fault code chart on the sticker inside the blower compartment door.
Continuous blower operation is usually caused by a thermostat fan switch set to ON rather than AUTO, a failed limit switch holding the blower relay closed, or a control board relay that has welded shut. Check the thermostat fan setting first before testing the limit switch and board.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.