Shop replacement repair parts for Trane Air Handler model TWE060D150B0

Capacitor; 440 vac oval motor run, 15 mfd

Blower motor, 3/4 HP, 1075 RPM, 200-230 volts, 60 amps, 1 phase

Filter; assembly, 20 x 22 x 1, semi-permanent

Capacitor; run, 15 mfd, 370vac, oval, w/o resistor
Maintain reliable airflow and system performance from your Trane TWE060D150B0 air handler with genuine OEM replacement parts from Repair Clinic. The TWE060D150B0 is a 5-ton electric heat air handler in Trane’s TWE series, the largest residential output class in this electric heat platform. The 060 capacity code identifies the 5-ton (60,000 BTU) output class; the D150 identifies the electric heat strip capacity. Parts most frequently replaced include the blower motor, run capacitor, control board, transformer, and limit switches. Use the TWE060D150B0 parts list and browse the full Trane air handler parts catalog.
The Trane TWE060D150B0 is the 5-ton (060) configuration in Trane’s TWE electric heat air handler series, the largest residential output class in this platform. The D150 in the model number identifies the electric heat strip capacity in this configuration. As the 5-ton configuration, the TWE060D150B0 blower motor moves the largest airflow volume in the TWE series; motors from smaller TWE configurations (TWE030, TWE048) are not interchangeable with the 5-ton 060 motor. The TWE series uses electric resistance heat strips for primary heating rather than a gas burner; this means the unit contains no combustion system, and service parts are blower, control, transformer, and heat element components. Limit switches in the TWE060D150B0 prevent electric heat element overtemperature; repeated limit trips indicate airflow restriction rather than a faulty switch in the majority of cases. The TWE060D150B0 manual documents blower speed tap settings and limit switch locations. For diagnostic guidance, visit the Trane air handler troubleshooting section.
The TWE060D150B0 blower motor moves the largest airflow volume in the TWE series and must maintain rated speed for safe electric heat operation at 5-ton output. A degraded run capacitor reduces motor torque and speed; test the TWE060D150B0 capacitor before condemning the motor. At 5-ton output, a motor running below rated speed reduces coil airflow more substantially than at smaller configurations. Browse Trane air handler blower motor parts.
The limit switches on the TWE060D150B0 shut down the electric heat elements when element temperature rises above the safe threshold. Repeated limit trips indicate airflow restriction from a clogged filter, blower motor running below rated speed from a degraded capacitor, or closed supply and return vents. Address airflow causes before replacing a limit switch; a correctly functioning limit switch trips when airflow is insufficient for safe electric heat operation, and the root cause must be addressed to prevent the replacement from tripping immediately.
The TWE060D150B0 transformer provides 24-volt power to the control board and thermostat circuit. Verify 24-volt output at the transformer secondary terminals before replacing the control board; transformer failure is significantly less costly and resolves board unresponsiveness in a substantial proportion of cases. Browse Trane air handler control board parts.
The TWE060D150B0 produces maximum condensate at 5-ton cooling capacity; a restricted drain line overflows the pan and triggers the float switch shutdown. Clear the drain line before resetting the float switch to prevent immediate repeat shutdown.
The Trane TWE060D150B0 is a 5-ton (60,000 BTU) electric heat air handler, the largest residential output class in Trane’s TWE series. The 060 capacity code identifies the 5-ton output class. Blower motors from smaller TWE configurations including the TWE030 and TWE048 are not interchangeable with the 5-ton 060 motor; confirm the 060 output class when ordering blower motor and capacitor components.
No. The Trane TWE060D150B0 is an electric resistance heat air handler; it contains no gas burner, heat exchanger, or combustion system. Heating is provided by electric resistance strips identified by the D150 heat capacity designation in the model number. Service parts are blower, control, transformer, heat element, and limit switch components. The TWE060D150B0 is paired with an outdoor condensing unit or heat pump for cooling.
Repeated limit switch trips on the TWE060D150B0 indicate insufficient airflow over the electric heat elements in the majority of cases. At 5-ton output with a full electric heat strip load, the blower must deliver the highest airflow in the TWE series to maintain safe element temperatures. Check the air filter for clogging first, then test the run capacitor microfarad value; a capacitor drifted below specification reduces blower speed and limits airflow below the threshold required for safe 5-ton heat element operation.
No. The TWE060D150B0 blower motor is sized for the 5-ton (060) output class and maximum airflow requirement in the TWE series. Motors from the TWE030 (2.5-ton) or TWE048 (4-ton) configurations produce insufficient airflow for safe 5-ton electric heat operation. Confirm the 060 capacity code when ordering a replacement blower motor for the TWE060D150B0.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic