Shop replacement repair parts for Bryant Central Air Conditioner model 561CJX030000AEAA

You need Contactor HN51KC024 if you're having trouble with the compressor or fan motor on your air conditioner, furnace, heat pump, or air handler. This genuine OEM single-pole, 24-volt coil contactor has a full load amps (FLA) rating of 30 amps and a locked rotor amps (LRA) rating of 150 amps.

Dual run capacitor round 440 V 35/5 uF

Capacitor start

Filter drier

Compressor h22j29babca
Protect your investment in the Bryant 561CJX030000AEAA with genuine OEM replacement parts from Repair Clinic. The 561CJX030000AEAA is a 2.5-ton single-stage cooling-only condensing unit in Bryant’s 561C series. Because Bryant and Carrier are sister brands under Carrier Global, the 561CJX030000AEAA and its Carrier equivalent at the same configuration share the same components; 561CJX030000AEAA parts ordered through either brand designation are interchangeable. Components that most frequently require service on this unit include the run capacitor, contactor, condenser fan motor, and control board. Use the 561CJX030000AEAA parts list and 561CJX030000AEAA diagram to confirm your component, then browse the complete Bryant central air conditioner parts catalog.
The Bryant 561CJX030000AEAA model number encodes the unit’s specifications and generation. The 561C identifies the product series within Bryant’s residential condensing unit line, the JX identifies the efficiency tier, 030 indicates 30,000 BTU (2.5-ton) capacity, and the AEAA suffix identifies the cabinet revision. Because Bryant and Carrier are Carrier Global sister brands sharing a single manufacturing platform, the 561CJX030000AEAA and its Carrier equivalent are the same physical unit. Parts sourced through the Bryant catalog and parts sourced through the Carrier catalog at the same configuration are identical and interchangeable. The 561CJX030000AEAA manual documents the refrigerant charge specification, electrical data, and component locations for this configuration. For diagnostic guidance, visit the Bryant central air conditioner troubleshooting section.
The 561CJX030000AEAA capacitor is a dual-run component that serves both the compressor and condenser fan motor in a single housing. As the capacitor’s microfarad value drifts below specification through thermal cycling over cooling seasons, the compressor and fan motor draw excess amperage to compensate for reduced start and run torque. The compressor hums briefly and shuts off, or the fan motor runs below rated speed while the compressor overheats against elevated head pressure. Test the capacitor with a microfarad meter at the start of each cooling season; replace it if either the compressor or fan motor section measures more than five percent below the rated value printed on the capacitor label. Browse Bryant central air conditioner capacitor parts for the correct 561CJX030000AEAA replacement.
The contactor on the 561CJX030000AEAA switches high-voltage power to the compressor and condenser fan motor each time the thermostat calls for cooling. Carbon deposits and physical pitting on the contact faces accumulate through thousands of switching cycles, increasing contact resistance and reducing the effective voltage delivered to the compressor motor. A unit that runs but delivers reduced cooling output with the compressor running hot and tripping its overload protector frequently often has a contactor that has degraded well below specification even though it still closes. Inspect the contact face surface visually as a first pass; replace the contactor if the contacts show visible pitting, blackening, or face erosion. Find compatible options at the Bryant air conditioner contactor page.
The condenser fan motor on the Bryant 561CJX030000AEAA draws ambient air upward through the condenser coil to reject heat from the refrigerant. Bearing wear in the motor produces a grinding or squealing noise that progresses to motor seizure, at which point the compressor overheats rapidly without the fan moving air across the coil. A unit that delivers reduced cooling capacity in high ambient temperatures before showing any audible symptoms may have a fan motor running below rated RPM due to early bearing wear. Replace the motor at first sign of bearing noise to prevent compressor damage from sustained high discharge pressure. Browse Bryant air conditioner fan motor parts.
The control board on the 561CJX030000AEAA coordinates the unit’s operational sequence, monitors safety inputs, and communicates with the thermostat system. A board fault typically presents as a unit that receives a thermostat call but does not energize the contactor, a compressor that starts without the fan motor following, or a unit that cycles erratically without satisfying the thermostat setpoint. Confirm 24-volt control circuit voltage at the board terminals before condemning the board; a failed transformer or thermostat communication wiring fault produces the same symptom at lower replacement cost. Browse Bryant air conditioner control board parts.
The condenser coil on the 561CJX030000AEAA transfers heat from the refrigerant to the outdoor air stream. Cottonwood seeds, grass clippings, and airborne debris compact between the coil fins over one to two seasons, reducing airflow and forcing the refrigerant to reject heat less efficiently. The result is elevated condensing pressure, higher compressor amperage, and reduced cooling capacity at the indoor unit. Annual coil cleaning with a low-pressure water rinse from the inside of the coil outward clears debris without damaging the fins. A coil with bent or crushed fins requires straightening to restore full airflow.
Yes. Bryant and Carrier are sister brands under Carrier Global sharing the same manufacturing platform. The capacitor, contactor, fan motor, and control board used in the 561CJX030000AEAA and its Carrier equivalent at the same BTU class are identical and fully interchangeable. Parts ordered under either brand designation fit correctly with no modification.
Test the 561CJX030000AEAA capacitor with a microfarad meter at the start of each cooling season. Replace it if either the compressor or fan motor section measures more than five percent below the rated microfarad value printed on the capacitor label. Do not rely on visual inspection alone; a capacitor that looks physically intact can be substantially out of specification.
The 561CJX030000AEAA contactor is a high-voltage switching relay that energizes the compressor and condenser fan motor when the thermostat calls for cooling. Replace it when the contact faces show visible pitting, blackening, or erosion, or when the unit hums briefly and then shuts off without cooling despite a confirmed good capacitor. Contactor replacement is recommended every five to seven years regardless of condition as preventive maintenance on this platform.
The 561CJX030000AEAA parts list and interactive diagram are available on the Repair Clinic listing page. The 561CJX030000AEAA manual is available through Bryant’s technical documentation portal and documents the refrigerant charge specification, electrical data, and component locations for this unit configuration.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic