Shop replacement repair parts for Lennox Air Conditioner model 14ACX-042-230-1


Panel-top

Maintain your 14ACX-042-230-1 central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The 14ACX-042-230-1 is a three-and-a-half-ton, 14 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The 14ACX designation identifies Lennox’s 14 SEER R-410A residential outdoor condensing unit series. The 042 identifies three-and-a-half-ton capacity, 230 identifies the 230-volt power configuration, and 1 identifies the production revision. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Lennox OEM parts for the 14ACX-042-230-1 including the Lennox capacitor parts, Lennox contactor parts, Lennox fan motor parts, and Lennox high-pressure switch parts. Browse the Lennox central air conditioner parts catalog filtered by 14ACX-042-230-1 for the complete parts inventory.
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the 14ACX-042-230-1. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
The 14ACX-042-230-1 is a three-and-a-half-ton, 14 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The 14ACX designation identifies Lennox’s 14 SEER R-410A residential outdoor condensing unit series. The 042 identifies three-and-a-half-ton capacity, 230 identifies the 230-volt power configuration, and 1 identifies the production revision.
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
The 14ACX-042-230-1 is a three-and-a-half-ton unit while the 14ACX-030-230-A18 is a two-and-a-half-ton unit in the same Lennox 14ACX 14 SEER R-410A series. The run capacitor carries different compressor-section microfarad ratings between the two tonnages.
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.