Shop replacement repair parts for AO Smith Water Heater model GCV40-200

Aluminum/zinc anode rod, 16"

Kit sec anode mag 2" nip 2ht 33" rod
The AO Smith GCV40-200 is a 40-gallon natural gas water heater with a standing pilot ignition system, designed for residential hot water demand in small to medium households. Unlike electronic-ignition water heaters with circuit boards and ignition modules, the GCV40-200’s standing pilot system is purely mechanical: thermocouple, pilot assembly, gas control valve, and burner assembly are the entire service universe. Repair Clinic stocks genuine AO Smith OEM parts for the GCV40-200 including pilot assembly 100109253 with thermocouple, gas control valve 100109217, anode rod 100109624, and temperature-pressure relief valve 100108279. Browse the AO Smith water heater parts catalog filtered by GCV40-200 for the complete parts list.
Most GCV40-200 service calls fall into two categories: the pilot will not stay lit, or the water is not reaching the correct temperature. A pilot that will not stay lit almost always means the thermocouple has weakened and can no longer generate adequate millivolt signal to hold the gas valve open after the knob is released. A gas control valve that fails to regulate temperature correctly should be confirmed with a thermometer before being replaced. The water heater repair help section covers standing pilot water heater thermocouple testing and gas valve diagnosis.
The pilot assembly on the GCV40-200 includes the pilot burner tube, spark igniter wire, and thermocouple as a single integrated unit. The thermocouple is the most common failure — when it weakens from heat cycling it can no longer generate adequate voltage to hold the gas valve open after the pilot is lit. AO Smith pilot assembly 100109253 replaces the complete assembly for natural gas GCV40-200 units.
The gas control valve on the GCV40-200 regulates both pilot gas and main burner gas flow, and contains the thermostat that controls water temperature. A valve that allows overheating, underheating, or that passes gas when in the pilot or off position requires replacement. AO Smith gas control valve 100109217 is the OEM replacement for the GCV40-200 natural gas configuration.
The main burner on the GCV40-200 heats the water in the tank when the gas control thermostat calls for heat. A burner that produces a yellow or orange flame rather than a clean blue flame is receiving inadequate combustion air or has a contaminated jet. A burner that does not light despite a functioning pilot has a thermocouple that is not generating enough voltage to open the main gas port in the control valve.
The sacrificial magnesium anode rod in the GCV40-200 protects the steel tank from corrosion. AO Smith anode rod 100109624 should be inspected every three to five years and replaced when it has corroded to less than half its original diameter. A GCV40-200 that produces sulfur-odor hot water has an anode rod that has been consumed and whose bare core wire is reacting with sulfate compounds in the water supply.
The T&P relief valve on the GCV40-200 is a critical safety device that opens to release water and steam if tank pressure or temperature exceeds safe limits. AO Smith T&P valve 100108279 is the OEM replacement. A valve that weeps continuously, will not reseat after a test lift, or has been in service for more than ten years should be replaced with a valve rated to the same pressure and temperature specifications as the original.
A pilot that lights but extinguishes when the control knob is released almost always has a failed or weakened thermocouple. The thermocouple generates the millivolt signal that holds the gas valve open. When it weakens, the valve closes and the pilot goes out as soon as the knob is released.
The thermocouple on the GCV40-200 is included as part of the pilot assembly. The pilot assembly part number is 100109253 for the GCV40-200-200 natural gas configuration. Use the full model number and serial number on Repair Clinic to confirm the correct pilot assembly for your production run.
Inspect the anode rod every three to five years. Replace it when corrosion has reduced its diameter to less than half of original or when more than six inches of core wire is exposed. The GCV40-200 anode rod part number is 100109624.
Sulfur or rotten egg odor in hot water is caused by a depleted magnesium anode rod whose bare steel core wire reacts with sulfate compounds in the water supply. Replacing the anode rod typically resolves the odor within one to two tank fills.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic