Shop replacement repair parts for ICP Central Air Conditioner model NAC036AKC3

1/4 HP 208-230Volts 60Hertz 1.4Amps 1100RPM Single Speed Closed Enclosure 48Y Frame Single Phase CW Rotation 1.75" Shaft

Compressor plug

Comp cr32k6-pfv-775
Maintain peak cooling performance from your ICP NAC036AKC3 central air conditioner with genuine OEM replacement parts from Repair Clinic. The NAC036AKC3 is a 3-ton single-stage cooling-only condensing unit in ICP’s NAC series, positioned above the NAC030AKC3 (2.5-ton) and NAC024AKC3 (2-ton) in the same platform generation. ICP (International Comfort Products) also markets this platform under the Heil, Tempstar, WeatherKing, and Arcoaire brand designations; parts ordered under any of these ICP brand channels at the same 3-ton NAC036 configuration are interchangeable. The NAC036AKC3 fan motor and fan blade are sized for the 3-ton condenser coil and are not interchangeable with the 2.5-ton NAC030AKC3 or 2-ton NAC024AKC3 components. Parts most frequently replaced include the run capacitor, contactor, condenser fan motor, and fan blade. Use the NAC036AKC3 parts list and browse the full ICP central air conditioner parts catalog.
The ICP NAC036AKC3 is the 3-ton (36,000 BTU) configuration in ICP’s NAC residential condensing unit series. The 036 designation in the model number is the critical specification for ordering fan motors and fan blades: the 3-ton 036 components are sized for the larger condenser coil surface area and are not interchangeable with the NAC030AKC3 (2.5-ton) motor and blade, nor with the NAC024AKC3 (2-ton) components. Installing an undersized motor from a lower tonnage configuration produces insufficient airflow for the 3-ton coil, raising condensing pressure and reducing cooling capacity. The ICP NAC036AKC3 shares its platform with Heil, Tempstar, WeatherKing, and Arcoaire equivalents at the same 3-ton configuration; if a NAC036AKC3 search returns no result for a specific component, searching under Heil or Tempstar at the same 036 output class will return compatible parts. The nac036akc3 manual documents refrigerant charge specification and component locations for the 3-ton configuration. For diagnostic guidance, visit the ICP air conditioner troubleshooting section.
The NAC036AKC3 capacitor is a dual-run unit serving the 3-ton compressor and condenser fan motor from a single housing. A 3-ton compressor draws higher locked-rotor amperage during startup than 2-ton or 2.5-ton units, making capacitor health more critical to compressor service life at this output class. Annual microfarad testing before cooling season is the highest-impact preventive maintenance step on the NAC036AKC3. Test both sections independently; replace the capacitor when either reads more than five percent below the rated value on the label. A compressor that hums briefly and then trips thermal protection while the fan runs normally has a failed compressor section. Browse ICP central air conditioner capacitor parts for the correct 036-class replacement.
The contactor on the ICP NAC036AKC3 switches line voltage to the 3-ton compressor and condenser fan motor at every thermostat cooling cycle. At 3-ton output the contactor handles higher switching current than 2-ton or 2.5-ton configurations, accelerating contact face arc erosion proportionally under equivalent seasonal use. Inspect the contact faces at each annual cooling season service; replace the NAC036AKC3 contactor when any pitting, blackening, or face erosion is visible. In warm climates where the unit operates for extended cooling seasons, proactive replacement every four to five years is cost-effective. Find compatible options at the ICP air conditioner contactor page.
The NAC036AKC3 motor drives the condenser fan that moves ambient air through the 3-ton coil to reject refrigerant heat. Bearing wear reduces operating RPM below the design point, cutting coil airflow and raising condensing pressure. At 3-ton output, a motor running below rated speed has a measurable impact on cooling capacity before the bearing fully fails; the unit may still cool the space but struggles to maintain setpoint in peak afternoon heat. Replace the motor at the first sign of bearing noise. When ordering, confirm the 036 output class designation; NAC030 and NAC024 motors produce incorrect airflow in the 3-ton NAC036 cabinet. Browse ICP central air conditioner fan motor parts.
The NAC036AKC3 fan blade is pitched for the 3-ton condenser coil airflow requirement at the motor’s rated RPM. A blade with a bent tip, surface corrosion, or a hub crack creates dynamic imbalance that vibrates the motor bearing during every cooling cycle. Inspect the blade annually for physical damage and replace the blade alongside the motor when damage is found, to protect the new motor’s bearing from the first cooling cycle. Confirm the blade diameter, pitch angle, and hub bore from the NAC036AKC3 parts list before ordering. Browse ICP central air conditioner fan blade parts.
The condenser coil on the NAC036AKC3 central a/c rejects heat from the refrigerant to the outdoor air stream. Debris accumulation on the coil fins raises condensing pressure above the design operating range, forcing the compressor to work against higher discharge pressure and reducing the unit’s effective cooling capacity. Annual coil cleaning at the start of cooling season with low-pressure water from inside the coil outward maintains the heat rejection efficiency the 3-ton compressor requires to operate within its design pressure range and extends compressor service life.
The ICP NAC036AKC3 is a 3-ton (36,000 BTU) condensing unit. The 036 in the model number identifies the output class. The fan motor and fan blade are sized for the 3-ton condenser coil; components from the NAC030AKC3 (2.5-ton) or NAC024AKC3 (2-ton) configurations are not interchangeable. Always confirm the 036 designation when ordering these components.
Heil, Tempstar, WeatherKing, and Arcoaire are ICP brand channels sharing the same manufacturing platform. Parts for the NAC036AKC3 under any of these designations at the same 3-ton 036 configuration are identical and interchangeable. If a NAC036AKC3-branded search returns no result for a specific component, searching under Heil or Tempstar at the same 036 output class will return compatible ICP NAC036AKC3 parts.
The nac036akc3 manual is available through ICP’s technical documentation portal and is referenced on the Repair Clinic listing page for this model. The manual documents the refrigerant charge specification, electrical data, component locations, and wiring diagrams for the 3-ton NAC036 configuration. Use it alongside the interactive NAC036AKC3 diagram to confirm part numbers for your specific component before ordering.
A NAC036AKC3 that runs continuously without satisfying the thermostat setpoint is most commonly caused by a degraded run capacitor reducing compressor and fan motor efficiency, a pitted contactor dropping supply voltage to the compressor, condenser coil debris restriction reducing heat rejection, or a fan motor running below rated RPM due to bearing wear. Inspect and test these four components in order before considering refrigerant charge as the cause of inadequate cooling at the 3-ton output class.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic