ICP Central Air Conditioner NXA624GKA100 Parts

Shop replacement repair parts for ICP Central Air Conditioner model NXA624GKA100

icons/central air condenser
Brand:ICP
Model:NXA624GKA100
Product:Central Air Conditioner
36 results
Product is a bestsellerProduct is a manufacturer part
1178917 Control Board Box
N/A

Kit control box cover

No Longer Available
Product is a bestsellerProduct is a manufacturer part
1178281 Screw
N/A

Screw #12ab x 5/8 hx hd sms

No Longer Available
Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
1174074 Condenser
N/A

Cond coil assy formed

No Longer Available
Go

ICP NXA624GKA100 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common ICP NXA624GKA100 problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Cleaner
Dual Run Capacitor
Contactor
Pump

Maintain your NXA624GKA100 central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The NXA624GKA100 is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. ICP, Heil, Tempstar, Arcoaire, and WeatherKing are all International Comfort Products brand designations sharing the same platform engineering and fully interchangeable service components. The NXA624GKA100 is the two-ton configuration in the ICP NXA6 series, below the four-ton NXA648GKA100. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine ICP OEM parts for the NXA624GKA100 including the ICP capacitor parts, ICP contactor parts, ICP fan motor parts, and ICP high-pressure switch parts. Browse the ICP central air conditioner parts catalog filtered by NXA624GKA100 for the complete parts inventory.

NXA624GKA100: Two-Ton Outdoor Condensing Unit Service

Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the NXA624GKA100. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.

Most Replaced Parts on the NXA624GKA100

Dual Run Capacitor for the NXA624GKA100

The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.

NXA624GKA100 Contactor

The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.

Outdoor Fan Motor for the NXA624GKA100

The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.

High-Pressure Switch for the NXA624GKA100

A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.

Why Choose Repair Clinic for NXA624GKA100 Parts

  • Genuine ICP NXA6 OEM Components: Two-ton dual run capacitors, contactors, and fan motors confirmed for the NXA624GKA100 with Heil, Tempstar, Arcoaire, and WeatherKing cross-reference ICP central air conditioner parts.
  • R-410A Puron Platform: The NXA624GKA100 uses R-410A refrigerant. Refrigerant circuit service requires EPA 608 certified technicians.
  • Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the NXA624GKA100.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

NXA624GKA100 Parts FAQ

What is the NXA624GKA100 and what ton size is it?

The NXA624GKA100 is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. ICP, Heil, Tempstar, Arcoaire, and WeatherKing are all International Comfort Products brand designations sharing the same platform engineering and fully interchangeable service components. The NXA624GKA100 is the two-ton configuration in the ICP NXA6 series, below the four-ton NXA648GKA100.

Why does my NXA624GKA100 hum but not start?

A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.

How does the ICP NXA624GKA100 differ from the NXA648GKA100?

The NXA624GKA100 is a two-ton unit while the NXA648GKA100 is a four-ton unit in the same ICP NXA6 series. The dual run capacitor carries different compressor-section microfarad ratings between the two tonnages.

How often should I test the capacitor on the NXA624GKA100?

Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.