Shop replacement repair parts for Goodman Air Handler model ARUF024-00A-1


Run capacitor, Single, Oval, 370 Volts, 5 Microfarads

Blower Motor. 1/6 HP, 208/230v 1075 RPM Requires a 5 mfd. 370v capacitor.

Transformer, 208/230, 24v
Restore reliable airflow from your Goodman ARUF024-00A-1 air handler with genuine OEM replacement parts from Repair Clinic. The ARUF024-00A-1 is a two-ton uncased upflow air handler from Goodman’s ARUF series, the smallest standard tonnage in the ARUF uncased lineup. The blower motor, run capacitor, and control board account for the majority of ARUF024-00A-1 service calls. Repair Clinic stocks genuine Goodman OEM parts for the ARUF024-00A-1 including the Goodman air handler blower motor parts, Goodman air handler capacitor parts, Goodman air handler control board parts, and Goodman air handler drain pan parts. Browse the Goodman air handler parts catalog filtered by ARUF024-00A-1 for the complete parts inventory.
The Goodman ARUF024-00A-1 is the smallest standard tonnage in the ARUF uncased air handler series, below the two-and-a-half-ton ARUF303016AA. The blower motor and run capacitor on the ARUF024-00A-1 are sized for the smaller two-ton airflow requirement and should not be cross-substituted with larger ARUF configurations. In heat pump applications the blower motor runs year-round, accumulating more annual hours than in cooling-only installations.
The two-ton blower motor is sized differently from larger ARUF configurations. In heat pump applications this motor runs year-round. Test the run capacitor before ordering a replacement motor.
The two-ton capacitor microfarad rating differs from larger ARUF configurations. A capacitor reading more than 10% below its rated value causes the motor to run hot at reduced airflow.
Confirm the full ARUF024-00A-1 designation from the data plate before ordering a replacement board.
A drain pan that overflows continuously has a clogged condensate drain outlet. Clear the drain line before replacing the pan.
The ARUF024-00A-1 is a two-ton uncased Goodman air handler. The 024 identifies 24,000 BTU two-ton capacity, the smallest standard tonnage in the ARUF uncased series.
No airflow is most commonly caused by a failed run capacitor preventing the blower motor from starting, a tripped circuit breaker, or a clogged filter restricting airflow. Check the filter and breaker before testing the capacitor and motor.
The ARUF024-00A-1 is a two-ton unit while the ARUF303016AA is a two-and-a-half-ton unit, both in the Goodman ARUF uncased air handler series. The blower motor and run capacitor are sized differently between the two configurations.
Yes. The ARUF024-00A-1 is compatible with Goodman and Daikin heat pumps and air conditioners in the two-ton R-410A category. In heat pump applications the blower runs year-round, making the run capacitor a higher-wear item.