Shop replacement repair parts for Goodman Air Handler model ARUF303016AA


Fan relay board

Blower motor, 1/3 hp, 3 speed, 6pl

Transformer, 208/230, 24v
Keep your Goodman ARUF303016AA air handler running reliably with genuine OEM replacement parts from Repair Clinic. The ARUF303016AA is a two-and-a-half-ton uncased upflow air handler from Goodman’s ARUF series, designed for installation in a dedicated air handler closet or with a field-supplied enclosure. In heat pump applications the blower motor runs year-round, accumulating more annual hours than in cooling-only installations. Repair Clinic stocks genuine Goodman OEM parts for the ARUF303016AA including the Goodman air handler blower motor parts, Goodman air handler capacitor parts, Goodman air handler control board parts, and Goodman air handler drain pan parts. Browse the Goodman air handler parts catalog filtered by ARUF303016AA for the complete parts inventory.
The Goodman ARUF303016AA is an uncased air handler requiring a field-supplied enclosure rather than a factory sheet-metal cabinet. The ARUF303016AA and ARUF303016BA are successive production revisions sharing most blower motor and coil components, but the control board may differ between the two revisions. Annual run capacitor testing before the cooling season is especially important in year-round heat pump applications.
In heat pump applications this motor runs year-round, accumulating more annual hours than in cooling-only installations. Test the run capacitor before ordering a replacement motor.
A capacitor reading more than 10% below its rated microfarad value causes the motor to run hot at reduced airflow. Annual testing before the cooling season catches a weakening capacitor before it fails.
Confirm the full ARUF303016AA designation including the AA revision suffix from the data plate before ordering a replacement board, as the AA and BA revisions may differ.
A drain pan that overflows continuously has a clogged condensate drain outlet. Clear the drain line before replacing the pan.
The ARUF303016AA is a two-and-a-half-ton uncased Goodman air handler. The 30 identifies approximately 30,000 BTU two-and-a-half-ton capacity and 16AA identifies the efficiency tier and production configuration within the ARUF uncased series.
The ARUF303016AA and ARUF303016BA are successive production revisions of the same two-and-a-half-ton ARUF uncased air handler. Most blower motor and coil components are shared between both revisions. The control board may differ between the AA and BA revisions.
Yes. The ARUF303016AA is compatible with Goodman and Daikin heat pumps and air conditioners in the two-and-a-half-ton R-410A category. In heat pump applications the blower runs year-round, making the run capacitor a higher-wear item.
No airflow is most commonly caused by a failed run capacitor preventing the blower motor from starting, a tripped circuit breaker, or a clogged filter restricting airflow. Check the filter and breaker before testing the capacitor and motor.