Shop replacement repair parts for Goodman Central Air Conditioner model CKL24-1F

Condenser fan motor, 1/6 HP 208-230Volts 60Hertz 1Amps 1075RPM Single Speed Closed Enclosure Single Phase CCW Rotation 2.5" Shaft

Dual run capacitor 440V 30/5 MFD
Maintain your CKL24-1F central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The CKL24-1F is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. The CKL24-1F is a production configuration within the Goodman CKL24 two-ton residential outdoor series. The CKL24 series includes the 1D, 1F, and related configurations at the same two-ton capacity. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Goodman OEM parts for the CKL24-1F including the Goodman capacitor parts, Goodman contactor parts, Goodman fan motor parts, and Goodman high-pressure switch parts. Browse the Goodman central air conditioner parts catalog filtered by CKL24-1F for the complete parts inventory.
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the CKL24-1F. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
The CKL24-1F is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. The CKL24-1F is a production configuration within the Goodman CKL24 two-ton residential outdoor series. The CKL24 series includes the 1D, 1F, and related configurations at the same two-ton capacity.
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
The CKL24-1F and CKL24-1D are different production configurations within the same two-ton Goodman CKL24 platform. The dual run capacitor, contactor, and outdoor fan motor are typically shared between configurations. Confirm the full designation before ordering a replacement control board.
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.