Shop replacement repair parts for Goodman Central Air Conditioner model CKL30-1D

Contactor, 2 pole, 30 amp, 24 vac **Special Note** This may replace single pole contactor and require a technican to install (based on model #)

Run cap 35/5mfd/440v/dual round

Condenser fan motor, 1/6 HP 208-230Volts 60Hertz 1Amps 1075RPM Single Speed Closed Enclosure Single Phase CCW Rotation 2.5" Shaft

Comp,30000,208/230/60/1

Filter drier
Keep your Goodman CKL30-1D central air conditioner performing efficiently with genuine OEM replacement parts from Repair Clinic. The CKL30-1D is a 2.5-ton single-stage cooling-only condensing unit in Goodman’s CKL series. The CKL30 designation identifies the 2.5-ton (30,000 BTU) output class; other CKL30 models including the CKL30-10 and CKL30-16 share many components with the CKL30-1D within the same output class, but the 1D, 10, and 16 revision suffixes may affect control board and wiring harness compatibility. Parts most frequently replaced on the Goodman CKL30-1D include the run capacitor, contactor, condenser fan motor, and fan blade. Use the CKL30-1D parts list and CKL30-1D diagram to confirm your component, then browse the complete Goodman central air conditioner parts catalog.
The Goodman CKL30-1D is part of the CKL30 output class within Goodman’s CKL condensing unit series. The 1D suffix identifies this specific revision of the 2.5-ton CKL30 platform; the CKL30-10 and CKL30-16 are earlier and later revisions within the same 2.5-ton output class. Capacitors, contactors, and fan motors are typically shared across CKL30 revision suffixes, but control boards and wiring harnesses may carry revision-specific part numbers; always confirm the 1D revision is covered in a specific control board listing before ordering. The CK30-1D is a related model designation that may appear in some parts catalogs and refers to the same CKL platform at the 2.5-ton class. The CKL30-1D manual documents the capacitor wiring configuration, component locations, and refrigerant charge specification. For diagnostic guidance, visit the Goodman central air conditioner troubleshooting section.
The CKL30-1D capacitor is a dual-run unit with separate sections for the compressor and condenser fan motor. The CKL30-1D manual and capacitor wiring diagram show the correct terminal connections for the compressor, fan, and common terminals; confirm these against your unit’s label before disconnecting the old capacitor to ensure correct reinstallation. Test both sections independently with a microfarad meter; replace the capacitor when either section reads more than five percent below the rated value on the capacitor label. A compressor section failure produces a compressor that hums and trips on thermal overload while the fan runs normally; a fan section failure produces a fan that does not start while the compressor runs. Browse Goodman central air conditioner capacitor parts.
The contactor on the Goodman CKL30-1D switches line voltage to the 2.5-ton compressor and condenser fan motor at every thermostat cooling cycle. Arc erosion accumulates on the contact faces through thousands of switching cycles, raising contact resistance and reducing the voltage delivered to the compressor motor. A CKL30-1D that starts and then shuts off within minutes on a hot day, or a compressor that trips its overload protector repeatedly under normal ambient temperatures, often has a contactor that has degraded well beyond acceptable resistance even when it still closes. Inspect the contact face surfaces at each annual cooling season service; replace the contactor when any pitting, blackening, or face erosion is visible. Find compatible options at the Goodman air conditioner contactor page.
The condenser fan motor on the Goodman CKL30-1D drives the fan that moves ambient air through the condenser coil to reject refrigerant heat. Bearing wear in the motor reduces its operating RPM below the rated design point, cutting coil airflow and raising condensing pressure. A CKL30-1D that cools adequately in mild weather but struggles in peak summer heat may have a fan motor running below rated speed before the bearing fully fails. Listen for a grinding or squealing noise at startup; replace the CKL30-1D fan motor at the first sign of bearing noise to prevent the compressor overload damage that follows from sustained high-discharge-pressure operation. Browse Goodman central air conditioner fan motor parts.
The CKL30-1D fan blade must be correctly balanced for the condenser fan motor’s rated RPM. A blade with a bent tip, surface corrosion along a vane, or a crack at the hub creates dynamic imbalance that vibrates the motor shaft bearing continuously during operation. Inspect the blade annually and replace it immediately if any physical damage is found, regardless of whether bearing noise has appeared; an imbalanced blade can progress from minor to severe bearing wear in a single cooling season. Confirm the blade diameter, pitch angle, and hub bore from the CKL30-1D parts list before ordering. Browse Goodman air conditioner fan blade parts.
Most CKL30-1D parts including the run capacitor, contactor, and fan motor are interchangeable with the CKL30-10 and CKL30-16 within the same 2.5-ton output class. Control boards and wiring harnesses may carry revision-specific part numbers; always confirm the 1D revision is covered in the specific listing for these components before ordering. The CKL30-1D parts list on the Repair Clinic listing page identifies which components are revision-specific.
The capacitor wiring diagram for the Goodman CKL30-1D is available in the CKL30-1D manual accessible through Goodman’s technical documentation portal and is also referenced on the Repair Clinic listing page for this model. The diagram shows the compressor, fan, and common terminal connections for the dual-run capacitor. Always photograph the existing wiring before disconnecting the old capacitor to confirm correct terminal assignment.
The Goodman CKL30-1D is a 2.5-ton (30,000 BTU) condensing unit. The 30 in the model designation identifies the 30,000 BTU output class. This is important when ordering the CKL30-1D fan motor and fan blade, which are sized for the 2.5-ton condenser coil and are not interchangeable with motors and blades from other CKL tonnage configurations.
A CKL30-1D compressor that hums briefly and then trips its thermal overload protector while the condenser fan runs normally has a failed compressor section on the dual-run capacitor. Test the capacitor compressor section microfarad value before any other diagnosis; this symptom resolves with capacitor replacement in the majority of cases without requiring compressor or contactor service.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic


