Goodman Air Conditioner CKL49-1L Parts

Shop replacement repair parts for Goodman Air Conditioner model CKL49-1L

icons/air conditioner
Brand:Goodman
Model:CKL49-1L
Product:Air Conditioner
22 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
CONT2P030024DS Contactor
$36.32

Contactor, 2 pole, 30 amp, 24 vac **Special Note** This may replace single pole contactor and require a technican to install (based on model #)

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0131M00847S Fan Motor
$103.64

Fan Motor 0131M00847S. One-speed, OEM replacement part designed specifically for Goodman and Amana HVAC equipment, like air conditioners, furnaces, and heat pumps. It operates at 1/4 HP, with electrical specifications of 208/230V and 1.4A and a rotation speed of 1075 RPM.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
CAP050400440RTP Dual Run Capacitor
$79.84

The Dual Run Capacitor CAP050400440RTP is a round capacitor with a 440-volt rating. If faulty, humidifiers, air conditioners, furnaces, packaged units/RTUs, heat pumps, air handlers, and central air conditioners may overheat. It's compatible with models from Amana and Goodman.

Product is a manufacturer part
Triple-D-AER Cleaner
$26.10

Triple-D Coil Cleaner is a 19oz Aerosol spray can, that is safe for homeowner use. One can will clean an entire outdoor condenser coil and/or indoor evaporator coil, to remove energy-stealing dirt, debris and soot.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1086775S Fan Blade
$91.49

21.5" fan blade (ccw, 1/2" bore, 25° pitch)

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
21986 Pump
$102.51

Condensate Pump.
Features:
* 16 foot lift
* Whisper quiet
* ½ Gallon Reservoir
* Rubber isolation feet
* 3/8" Check Valve

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0151R00078S Service Valve
N/A

Service Valve 3/8

No Longer Available
Go

Goodman CKL49-1L Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Goodman CKL49-1L problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Contactor
Fan Motor
Dual Run Capacitor
Cleaner

Ensure your CKL49-1L central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The CKL49-1L is a four-ton residential outdoor condensing unit using R-410A Puron refrigerant. The CKL49-1L is a four-ton configuration within the Goodman CKL49 residential outdoor condensing unit series. Goodman, Daikin, and Amana are related brands under the same parent company. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Goodman OEM parts for the CKL49-1L including the Goodman capacitor parts, Goodman contactor parts, Goodman fan motor parts, and Goodman high-pressure switch parts. Browse the Goodman central air conditioner parts catalog filtered by CKL49-1L for the complete parts inventory.

CKL49-1L: Four-Ton Outdoor Condensing Unit Service

Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the CKL49-1L. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.

Most Replaced Parts on the CKL49-1L

Dual Run Capacitor for the CKL49-1L

The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.

CKL49-1L Contactor

The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.

Outdoor Fan Motor for the CKL49-1L

The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.

High-Pressure Switch for the CKL49-1L

A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.

Why Choose Repair Clinic for CKL49-1L Parts

  • Genuine Goodman CKL49 OEM Components: Four-ton dual run capacitors, contactors, and fan motors confirmed for the CKL49-1L platform Goodman central air conditioner parts.
  • R-410A Puron Platform: The CKL49-1L uses R-410A refrigerant. Refrigerant circuit service requires EPA 608 certified technicians.
  • Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the CKL49-1L.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

CKL49-1L Parts FAQ

What is the CKL49-1L and what ton size is it?

The CKL49-1L is a four-ton residential outdoor condensing unit using R-410A Puron refrigerant. The CKL49-1L is a four-ton configuration within the Goodman CKL49 residential outdoor condensing unit series. Goodman, Daikin, and Amana are related brands under the same parent company.

Why does my CKL49-1L hum but not start?

A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.

What refrigerant does the Goodman CKL49-1L use?

Confirm the refrigerant type from the unit data plate, as older Goodman CKL series units may use R-22 depending on the specific production year. Always verify before ordering refrigerant circuit components, since R-22 service requires EPA 608 certified technicians.

How often should I test the capacitor on the CKL49-1L?

Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.