Shop replacement repair parts for Goodman Air Conditioner model GSC130601BC

Fan motor 1/6 hp 835 rpm 208/230 vac 1 ph 60 hz
Restore your GSC130601BC central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The GSC130601BC is a five-ton, 13 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The 060 identifies 60,000 BTU five-ton capacity, the largest standard tonnage in the GSC13 series, and BC identifies the production configuration within the GSC130601 series alongside the GSX130601BA on the related GSX13 platform. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Goodman OEM parts for the GSC130601BC including the Goodman capacitor parts, Goodman contactor parts, Goodman fan motor parts, and Goodman high-pressure switch parts. Browse the Goodman central air conditioner parts catalog filtered by GSC130601BC for the complete parts inventory.
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the GSC130601BC. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
The GSC130601BC is a five-ton, 13 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The 060 identifies 60,000 BTU five-ton capacity, the largest standard tonnage in the GSC13 series, and BC identifies the production configuration within the GSC130601 series alongside the GSX130601BA on the related GSX13 platform.
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
The GSC130601BC and GSX130601BA are both five-ton 13 SEER Goodman residential outdoor units from related GSC13 and GSX13 series. The BC and BA suffixes identify different production configurations, and service components may differ between the two series. Always confirm the full model designation before ordering.
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic