Shop replacement repair parts for Nordyne Central Air Conditioner model JS3BA-024KA

Contactor 1 pole, 25fla, 24v

1/10HP 208-230Volts 60Hertz 0.7Amps 1100RPM Single Speed Closed Enclosure 42Y Frame Single Phase CW Rotation 1.5" Shaft

18" cw fan blade with 1/2" bore, 3 blades
Restore your JS3BA-024KA central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The JS3BA-024KA is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. Nordyne is the parent platform for Coleman HVAC, Gibson, and related manufactured home and residential HVAC brands. The JS3BA-024KA is a two-ton configuration in the JS3BA series, distinct from the JS5BD-024KB and S3BA-024KA at the same tonnage. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Nordyne OEM parts for the JS3BA-024KA including the Nordyne capacitor parts, Nordyne contactor parts, Nordyne fan motor parts, and Nordyne high-pressure switch parts. Browse the Nordyne central air conditioner parts catalog filtered by JS3BA-024KA for the complete parts inventory.
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the JS3BA-024KA. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
The JS3BA-024KA is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. Nordyne is the parent platform for Coleman HVAC, Gibson, and related manufactured home and residential HVAC brands. The JS3BA-024KA is a two-ton configuration in the JS3BA series, distinct from the JS5BD-024KB and S3BA-024KA at the same tonnage.
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
The JS3BA-024KA and S3BA-024KA are both two-ton configurations within the Nordyne platform but represent different product series designations. Always confirm the full series designation from the unit data plate before ordering a control board, as the JS3BA and S3BA series may have different component specifications.
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.