Shop replacement repair parts for Nordyne Central Air Conditioner model S3QA-036KA

Dual Run Capacitor 370 Volt Round Dual 50/5 MFD

Fan motor, 208/230Volts 60Hertz 1.15/1.18Amps 1075RPM Single Speed Closed Enclosure 42Y Frame Single Phase CW Rotation 2.25" Shaft
Keep your S3QA-036KA central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The S3QA-036KA is a three-ton residential outdoor condensing unit using R-410A Puron refrigerant. Nordyne is the parent platform for Coleman HVAC, Gibson, and related manufactured home and residential HVAC brands. Service components for the S3QA-036KA are interchangeable with equivalent Nordyne platform models at the same tonnage configuration. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Nordyne OEM parts for the S3QA-036KA including the Nordyne capacitor parts, Nordyne contactor parts, Nordyne fan motor parts, and Nordyne high-pressure switch parts. Browse the Nordyne central air conditioner parts catalog filtered by S3QA-036KA for the complete parts inventory.
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the S3QA-036KA. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A capacitor reading more than 10% below its rated microfarad value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
The contactor closes the 240-volt compressor power circuit at every cooling cycle start. Pitted or burned contact surfaces generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
The S3QA-036KA is a three-ton residential outdoor condensing unit using R-410A Puron refrigerant. Nordyne is the parent platform for Coleman HVAC, Gibson, and related manufactured home and residential HVAC brands. Service components for the S3QA-036KA are interchangeable with equivalent Nordyne platform models at the same tonnage configuration.
A unit that hums but does not start has most commonly failed at the dual run capacitor, which cannot provide adequate starting torque to the compressor or fan motor. Test the capacitor with a digital capacitance meter before testing any other component.
Nordyne is the parent platform for Coleman HVAC, Gibson, and other residential HVAC brands. The S3QA-036KA and its Coleman HVAC equivalent at the same configuration share the same platform engineering with interchangeable service components.
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic