Shop replacement repair parts for Rheem Air Conditioner model RAKA-037JAZ/Serial: 5429

Run Capacitor 370 Volts Round Dual 50/3 MFD
Restore and maintain peak cooling performance from your Rheem RAKA-037JAZ with genuine OEM replacement parts from Repair Clinic. The RAKA-037JAZ is a 3-ton (approximately 37,000 BTU) single-stage cooling-only condensing unit in Rheem’s RAKA series, sharing its platform fully with the Ruud UAKA-037JAZ; Rheem and Ruud are the same manufacturer, and all replacement parts are interchangeable between the two brand designations with no modification. Parts most frequently replaced on the Rheem RAKA-037JAZ include the run capacitor, contactor, condenser fan motor, and start relay. The 037 in the RAKA-037JAZ model number indicates approximately 37,000 BTU cooling capacity, corresponding to a 3-ton system. Browse the full Rheem air conditioner parts catalog.
The Rheem RAKA-037JAZ is designed for residential ground-level pad installation, but the RAKA series is also deployed in light commercial settings where units are roof-mounted. Rooftop installations expose the cabinet to direct solar gain that raises ambient temperature inside the electrical compartment, accelerating capacitor dielectric degradation and contactor pitting significantly faster than shaded pad installations. A RAKA-037JAZ operating on a sun-exposed roof should have its run capacitor tested annually at the start of cooling season rather than on a standard two-to-three-year replacement cycle. Test annually before peak cooling demand begins. For diagnostic guidance, visit the Rheem air conditioner repair help section.
The run capacitor on the RAKA-037JAZ serves the compressor and condenser fan motor simultaneously in a dual-run configuration. As the capacitor’s microfarad value drifts below rated specification, the compressor draws higher amperage to compensate for reduced start and run torque, shortening compressor service life. A unit that starts and runs but trips the breaker on hot days, or a compressor that hums briefly before shutting off, points to a capacitor that has drifted out of tolerance. Test the capacitor with a microfarad meter before assuming a compressor fault. Browse Rheem air conditioner capacitor parts.
The contactor switches high-voltage power to the compressor and condenser fan motor each time the thermostat calls for cooling. Over thousands of switching cycles, the contact surfaces pit and develop carbon deposits that increase resistance and reduce the voltage delivered to the compressor. Visual inspection of contact surface pitting is faster than electrical testing as a first-pass diagnosis. Browse Rheem air conditioner contactor parts.
The condenser fan motor draws ambient air through the condenser coil to reject heat from the refrigerant. Bearing wear produces a grinding or squealing noise that progressively worsens before the motor seizes, at which point the compressor overheats without the fan drawing air across the coil. A unit that sounds normal but produces inadequate cooling in high ambient temperatures may have a fan motor running below rated RPM before the bearing fully seizes. Replace the motor at the first sign of bearing noise. Browse Rheem air conditioner condenser fan motor parts.
The start relay assists the compressor motor during startup by briefly connecting the start capacitor in the compressor circuit. A failed start relay either stays in circuit continuously, overloading the start winding, or drops out too early, preventing the compressor from reaching operating speed. If the unit hums on startup without the compressor running, test the start relay before condemning the compressor.
Cottonwood seeds, grass clippings, and airborne debris compact between the condenser coil fins over one to two seasons, reducing airflow and forcing the refrigerant to reject heat less efficiently. Annual coil cleaning with a low-pressure water rinse from the inside of the coil outward clears debris without damaging fin edges. Browse Rheem air conditioner fan blade parts if blade damage accompanies coil debris buildup.
Yes. Rheem and Ruud share a single manufacturing platform, and the RAKA-037JAZ and UAKA-037JAZ are the same condensing unit sold under different brand labels. All replacement parts are fully interchangeable between the two brand designations with no modification required.
The 037 in the RAKA-037JAZ model number indicates approximately 37,000 BTU cooling capacity, which corresponds to a 3-ton system. The RAKA series encodes tonnage directly in the model number, making it straightforward to confirm system sizing when ordering replacement components.
Test the run capacitor annually at the start of each cooling season. For RAKA-037JAZ units in high-thermal-stress locations such as rooftop or direct-sun exposures, annual testing is especially important because heat accelerates capacitor dielectric degradation faster than shaded pad installations. Replace immediately if the measured microfarad value is more than five percent below the rated value on the capacitor label.
Reduced cooling output with the unit running is most commonly caused by a degraded run capacitor reducing compressor and fan motor efficiency, a pitted contactor dropping voltage to the compressor, or a condenser coil restricted by debris reducing heat rejection. Inspect and test these three components in order before considering refrigerant charge as a cause. Refrigerant circuit work requires an EPA 608 certified technician.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic