Shop replacement repair parts for WeatherKing Central Air Conditioner model 13AJA30A01/Serial: 7403

Contactor, 24 volts, 30 amps, 1pole

Run Capacitor 370 Volts Round Dual 45/5 MFD

Condenser motor - 1/6, hp 208-230/1/50-60 (850rpm)
Restore reliable cooling from your WeatherKing 13AJA30A01 central air conditioner with genuine OEM replacement parts from Repair Clinic. The 13AJA30A01 is a 2.5-ton 13-SEER single-stage cooling-only condensing unit in the WeatherKing 13AJA series. WeatherKing is part of the ICP (International Comfort Products) family that includes Heil, Tempstar, and Arcoaire; all four brands share the same manufacturing platform, and parts ordered under any of these designations at the same configuration are interchangeable. The serial prefix 7403 in the 13AJA30A01/Serial: 7403 designation identifies the production date range; for capacitors, contactors, fan motors, and fan blades, this serial prefix does not affect compatibility. The keyword 13AJA30A01/Serial: 7403 carburetor appearing in some catalog searches does not apply to this unit; the 13AJA30A01 is a refrigerant-based air conditioning system with no carburetor or fuel system components. Parts most frequently replaced include the run capacitor, contactor, condenser fan motor, and control board. Use the 13AJA30A01/Serial: 7403 parts list and browse the full ICP central air conditioner parts catalog to confirm fit.
The WeatherKing 13AJA30A01 model number encodes the unit’s configuration: 13AJA identifies the series within WeatherKing’s 13-SEER condensing line, 30 indicates the 2.5-ton (30,000 BTU) output class, and A01 is the cabinet revision. The serial prefix 7403 in the 13AJA30A01/Serial: 7403 designation identifies the production week and year; for most service components the serial date has no impact on parts selection within the 13AJA30A01 model. WeatherKing is an ICP brand, and the 13AJA30A01 is identical to Heil, Tempstar, and Arcoaire units at the same 2.5-ton 13AJA configuration. If a parts search under the WeatherKing designation returns no result for a specific component, searching under Heil or Tempstar at the same model number will return compatible components. The 13AJA30A01/Serial: 7403 manual documents refrigerant charge specifications, electrical data, and component locations for the 2.5-ton platform. For diagnostic guidance, visit the ICP central air conditioner troubleshooting section.
The 13AJA30A01/Serial: 7403 capacitor is a dual-run unit serving the 2.5-ton compressor and condenser fan motor. Annual testing with a microfarad meter that reads both sections independently is the highest-impact preventive maintenance step on this unit. Replace the capacitor when either the compressor or fan motor section reads more than five percent below the rated value on the capacitor label. A compressor that hums briefly and then trips on thermal protection while the fan runs normally has a failed compressor section; a fan that does not start while the compressor runs has a failed fan motor section. Test both sections before replacing the capacitor based on symptoms alone. Browse ICP central air conditioner capacitor parts for the correct 13AJA30A01 replacement.
The contactor on the WeatherKing 13AJA30A01 switches line voltage to the 2.5-ton compressor and condenser fan motor at every thermostat cooling cycle. Arc erosion accumulates on the contact faces through thousands of switching cycles, increasing contact resistance and reducing the effective voltage delivered to the compressor motor. In warm climates where the 13AJA30A01 operates for extended cooling seasons, contact erosion reaches problematic levels in three to four years rather than the five to seven year interval typical in northern climates. Inspect the contact faces at each annual cooling season service and replace the contactor when visible pitting or erosion is present. Find compatible options at the ICP air conditioner contactor page.
The condenser fan motor on the 13AJA30A01/Serial: 7403 central air conditioner moves ambient air through the condenser coil to reject refrigerant heat. Bearing wear reduces the motor’s operating RPM below the rated design point, cutting coil airflow and raising condensing pressure. The symptom of reduced heat rejection appears as a unit that satisfies the thermostat in mild weather but struggles to maintain setpoint in peak afternoon heat before the motor bearing fully fails. Replace the motor at the first sign of bearing noise to prevent the compressor overload damage that follows from sustained elevated condensing pressure. Browse ICP central air conditioner fan motor parts.
The control board on the WeatherKing 13AJA30A01 manages the unit’s operational sequence, monitors safety inputs, and communicates with the thermostat or communicating control system. A board fault presents as a unit that does not respond to a thermostat cooling call, a compressor that starts without the condenser fan, or a unit that cycles erratically. Before ordering a control board replacement, verify 24-volt control circuit voltage at the board input terminals and confirm the thermostat is sending a valid cooling call; a failed 24-volt transformer or broken low-voltage wiring produces identical symptoms at lower replacement cost. Browse ICP central air conditioner control board parts.
No. The WeatherKing 13AJA30A01 is a refrigerant-based central air conditioning system; it has no carburetor, fuel system, or engine components. The carburetor search term appearing in some catalog queries for this model number is a search indexing artifact and does not correspond to any actual component in the 13AJA30A01/Serial: 7403 air conditioner.
Heil, Tempstar, and Arcoaire are all ICP (International Comfort Products) brands sharing the same manufacturing platform as WeatherKing. Parts for the 13AJA30A01 under any of these brand designations at the same 2.5-ton configuration are identical and interchangeable. If a WeatherKing designation search returns no result, searching under Heil or Tempstar at the same model number pattern will return compatible components.
The 7403 serial prefix identifies the production week and year of manufacture for this specific unit. For the run capacitor, contactor, fan motor, and fan blade, this serial date has no impact on parts compatibility within the 13AJA30A01 model. For control boards and wiring harnesses, confirm the serial range is covered in the specific listing before ordering to ensure the correct production generation component.
A 13AJA30A01 that runs continuously without satisfying the thermostat setpoint is most commonly caused by a degraded run capacitor reducing compressor and fan motor efficiency, a pitted contactor dropping supply voltage to the compressor, condenser coil debris restriction reducing heat rejection, or a fan motor running below rated RPM due to bearing wear. Inspect and test these four components in order before considering refrigerant charge as the cause.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic