Shop replacement repair parts for Ruud Central Air Conditioner model UAMB-042JAZ/Serial: 6265

Contactor, 24 volts, 30 amps, 1pole

24v 32a 3pole contactor
Service your Ruud UAMB-042JAZ central air conditioner with genuine OEM replacement parts from Repair Clinic. The UAMB-042JAZ is a 3.5-ton single-stage cooling-only condensing unit in Ruud’s UAMB series. The serial prefix 6265 in the UAMB-042JAZ/Serial: 6265 designation identifies the production week and year of manufacture. Because Ruud and Rheem are sister brands sharing the same manufacturing platform, the UAMB-042JAZ and its Rheem equivalent at the same 3.5-ton configuration use identical components. The UAKA-042JAZ is a related prior-series designation in the same Ruud-Rheem family at the same 3.5-ton output class; many components are shared between the UAMB and UAKA series. Parts most frequently replaced include the run capacitor, contactor, condenser fan motor, and fan blade. Use the UAMB-042JAZ/Serial: 6265 parts list and browse the full Ruud central air conditioner parts catalog.
The Ruud UAMB-042JAZ is a 3.5-ton (42,000 BTU) condensing unit. The 042 in the model number identifies the 3.5-ton output class; the UAMB-042JAZ fan motor and blade are sized for the 3.5-ton condenser coil and are not interchangeable with UAMB components from the UAMB-036JAZ (3-ton) or UAMB-048JAZ (4-ton) configurations. The serial prefix 6265 in the UAMB-042JAZ/Serial: 6265 identifies the production week and year; for run capacitors, contactors, fan motors, and fan blades, this serial date has no impact on parts selection within the UAMB-042JAZ model. The UAKA-042JAZ is a prior-series designation in the same Ruud-Rheem condensing unit family at the same 3.5-ton output class; the UAKA series preceded the UAMB series, and most service components at the same tonnage including the run capacitor, contactor, and fan motor are interchangeable between the UAKA-042JAZ and UAMB-042JAZ. For diagnostic guidance, visit the Ruud air conditioner troubleshooting section.
The UAMB-042JAZ/Serial: 6265 capacitor is a dual-run unit serving the 3.5-ton compressor and condenser fan motor. Annual microfarad testing before cooling season is essential; replace the capacitor when either section reads more than five percent below the rated value. At 3.5-ton output the compressor draws higher amperage than 2-ton or 3-ton units during startup; a degraded capacitor produces proportionally higher overload stress per startup cycle. Browse Ruud central air conditioner capacitor parts.
The contactor on the Ruud UAMB-042JAZ switches line voltage to the 3.5-ton compressor and condenser fan motor. At 3.5-ton output the switching load is higher than 2-ton or 3-ton configurations. Inspect the contact faces at each annual service; replace the UAMB-042JAZ contactor when any pitting or erosion is visible. Find compatible options at the Ruud air conditioner contactor page.
The UAMB-042JAZ/Serial: 6265 fan motor is sized for the 3.5-ton condenser coil airflow requirement. Many fan motors are shared between the UAMB-042JAZ and the prior-series UAKA-042JAZ at the same 3.5-ton output class; confirm the part number matches for your specific model before assuming interchangeability. Replace the motor at the first sign of bearing noise. Browse Ruud central air conditioner fan motor parts.
The UAMB-042JAZ/Serial: 6265 fan blade is pitched for the 3.5-ton coil airflow. Inspect annually for physical damage; confirm the blade specification from the UAMB-042JAZ parts list. Browse Ruud central air conditioner fan blade parts.
The Ruud UAMB-042JAZ is a 3.5-ton (approximately 42,000 BTU) condensing unit. The 042 in the model number identifies the 3.5-ton output class. Fan motors and blades must be specified for the 042 (3.5-ton) output class and are not interchangeable with UAMB components from the 036 (3-ton) or 048 (4-ton) configurations in the same series.
Many components including the run capacitor, contactor, and fan motor are interchangeable between the UAMB-042JAZ and the prior-series UAKA-042JAZ at the same 3.5-ton output class. The UAKA is the prior-series designation within the same Ruud-Rheem condensing unit family. Control boards and wiring harnesses may carry series-specific part numbers; confirm the UAMB designation is covered in the specific listing before ordering these components from UAKA listings.
The 6265 serial prefix identifies the production week and year of manufacture. For the run capacitor, contactor, fan motor, and fan blade, this serial date has no impact on parts compatibility within the UAMB-042JAZ model. For control boards and wiring harnesses, confirm the serial range is covered in the specific listing before ordering.
Yes. Ruud and Rheem are sister brands sharing the same manufacturing platform under Rheem Manufacturing. The UAMB-042JAZ and its Rheem equivalent at the same 3.5-ton configuration are identical units. Run capacitors, contactors, fan motors, and fan blades are fully interchangeable across Ruud and Rheem brand designations at the same output class and series.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.