Shop replacement repair parts for Kenmore Washer/Dryer Combo model 110.97561100

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer gas burner valve solenoid set. If the dryer does not heat or heats intermittently the coils could be defective. To test, watch the burner and if the igniter glows for a while and then shuts off without the gas igniting, it usually means one of these coils is bad.

Dryer drum drive motor with pulley

Gas dryer sensor for igniter and flame. The sensor is located across from the gas igniter at the dryer’s burner assembly. This flame sensor should be closed for continuity at room temperature. Check for continuity with a multi-meter before replacing.

Dryer timer