Shop replacement repair parts for Bradford White Water Heater model MI40T6FBN

Gas valve assembly

Natural gas valve kit, 160 degrees F
Maintain reliable hot water from your Bradford White MI40T6FBN with genuine OEM replacement parts from Repair Clinic. The model decodes as a 40-gallon (40), tall tank (T) natural gas (N) atmospheric water heater with Bradford White’s FVIR Defender Safety System (F). Parts that most often need replacement include the thermocouple and pilot assembly, the gas valve, the MI40T6FBN anode rod, and the dip tube and fittings. Locate each part on the MI40T6FBN parts list, then browse the complete selection of Bradford White water heater parts.
Because this is a gas model, there is no electric MI40T6FBN heating element: the main burner under the tank does that job, and slow recovery is usually a burner, venting, or gas valve issue. Likewise, the MI40T6FBN thermostat is built into the gas control valve, so a thermostat that will not regulate is solved by replacing the valve assembly. The FVIR system adds a flame arrestor and a thermal shutoff that stop the burner if abnormal combustion chamber temperatures are detected. Lint or dust on the arrestor screen is a common trigger, so clean the air intake before replacing safety parts. The tall tank is dimensionally different from the short MI403S6FBN, even though the two share many components. The MI40T6FBN manual and MI40T6FBN diagram show part locations. For MI40T6FBN repair steps, visit the water heater troubleshooting page.
When the pilot lights but goes out as soon as you release the pilot button, the thermocouple is the first suspect: it generates the small voltage that holds the gas valve’s safety seat open. Test the thermocouple before suspecting the gas valve. If a new thermocouple does not hold the pilot, inspect the pilot orifice for debris and replace the complete pilot assembly.
If the heater shuts down and the pilot will not relight, check the flame arrestor and air intake first. Depending on the build, the thermal switch may be resettable or may require replacement; your diagram shows which. Replace the gas valve assembly when the thermocouple tests good, the arrestor is clean, and the valve still will not hold the pilot or regulate temperature.
The sacrificial anode rod corrodes in place of the steel tank. Inspect it every two to five years, more often with hard or softened water. Replace it when the core wire is exposed or the rod has worn to less than half its original diameter. A rotten egg smell from the hot water often means the rod has reacted with the water supply. Order a matching anode rod.
The MI40T6FBN dip tube carries cold inlet water to the bottom of the tank. When it cracks or breaks, cold water mixes with hot water at the top, so the heater seems to run out quickly and plastic fragments may collect in faucet aerators. Replacements are in the hose, tube, and fitting category.
A weak thermocouple is the most common cause. If the pilot lights but goes out when you release the button, replace the thermocouple first. If a new one does not help, check the pilot orifice and then the gas valve.
No. This is a natural gas model, so the main burner heats the tank. Searches for an element on the MI40T6FBN usually mean the burner assembly or gas control valve.
Inspect it every two to five years, sooner with hard or softened water. Replace it when the core wire shows or the rod has lost half its diameter.
Hot water that runs out fast or turns lukewarm, plus small plastic pieces in faucet aerators. A broken tube lets cold inlet water mix with hot water at the top of the tank.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic