Shop replacement repair parts for Carrier Central Air Conditioner model CA14NA03600GAAAA

Motor,fan 1/5 hp 1 phase

Compressor, scroll

Wire harness assy r-410a
Keep your CA14NA03600GAAAA central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The CA14NA03600GAAAA is a three-ton, 14 SEER R-410A Comfort Series residential outdoor condensing unit using R-410A Puron refrigerant. Carrier and Bryant are sister brands under the same parent company. All service components are interchangeable between both brand designations at the same configuration. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Carrier OEM parts for the CA14NA03600GAAAA including the Carrier capacitor parts, Carrier contactor parts, Carrier fan motor parts, and Carrier high-pressure switch parts. Browse the Carrier central air conditioner parts catalog filtered by CA14NA03600GAAAA for the complete parts inventory.
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the CA14NA03600GAAAA. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
The CA14NA03600GAAAA is a three-ton, 14 SEER R-410A Comfort Series residential outdoor condensing unit using R-410A Puron refrigerant. Carrier and Bryant are sister brands under the same parent company. All service components are interchangeable between both brand designations at the same configuration.
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
The CA14NA03600GAAAA is a 14 SEER unit while the CA16NA03600GAAAA is a 16 SEER unit at the same three-ton capacity. The CA14NA and CA16NA are different SEER-tier platforms with different component specifications. Always confirm the full CA14NA or CA16NA designation before ordering any replacement part.
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.