Shop replacement repair parts for Maytag Dryer model MDG20PDAXW0

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer door switch assembly. If the dryer does not start then the door switch could be defective. This switch also replaces the two wire switch.

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Thermal cutoff

Drive belt

Thermostat, high-limit 255 f

Dryer drum drive motor kit

Panel-cntl

Pulley-idr

Service Access Door Switch for the Vault

Cntrl-elec

Electronic control