Restore your ASPT61D14AC air handler running reliably with genuine OEM replacement parts from Repair Clinic. The ASPT61D14AC is a five-ton residential air handler. The ASPT designation identifies Goodman’s upflow cased air handler series. The 61D14 capacity coding identifies five-ton capacity, the largest standard residential configuration in the ASPT platform. Goodman, Daikin, and Amana are related brands under the same parent company. The blower motor, run capacitor, and control board account for the majority of ASPT61D14AC service calls. Repair Clinic stocks genuine Goodman OEM parts for the ASPT61D14AC including the Goodman air handler blower motor parts, Goodman air handler capacitor parts, Goodman air handler control board parts, and Goodman air handler drain pan parts. Browse the Goodman air handler parts catalog filtered by ASPT61D14AC for the complete parts inventory.
The blower motor and run capacitor on the ASPT61D14AC are sized for five-ton airflow requirements. In heat pump applications the blower runs year-round, making annual run capacitor testing especially important. Annual condensate drain line flushing prevents the overflow that causes the most common water leak complaint.
In heat pump applications this motor runs year-round. Test the run capacitor before ordering a replacement motor.
A reading more than 10% below the rated microfarad value causes the blower motor to run hot at reduced airflow.
Confirm the full model designation from the data plate before ordering. A board fault typically presents as the unit not responding to thermostat commands.
Clear the drain line completely before replacing the pan.
The ASPT61D14AC is a five-ton residential air handler. The ASPT designation identifies Goodman’s upflow cased air handler series. The 61D14 capacity coding identifies five-ton capacity, the largest standard residential configuration in the ASPT platform. Goodman, Daikin, and Amana are related brands under the same parent company.
No airflow is most commonly caused by a failed run capacitor preventing the blower motor from starting, a tripped circuit breaker, or a clogged air filter. Check the filter and breaker before testing the capacitor and motor.
The ASPT61D14AC is a five-ton unit while the ASPT49D14AC is a four-ton unit in the same Goodman ASPT cased air handler series. The five-ton blower motor and run capacitor are sized for greater airflow than the four-ton configuration and are not interchangeable.
Water leaking is most commonly caused by a clogged condensate drain line causing the drain pan to overflow. Clear the drain line completely before replacing the drain pan.