Shop replacement repair parts for Maytag Dryer model MDG28PDCXW0

Dryer thermal fuse. Opens at approximately 196°F (91°C). *If open check for air flow issues like plugged exhaust vent or damaged blower wheel

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Thermal cutoff

Drive belt

Thermostat, high-limit 255 f

Dryer drive motor assembly with step-up belt system for blower wheel

Idler pulley assembly

Console asm- dryer, wht

Broken belt switch

Switch-dor

Console

Service Access Door Switch for the Vault

Main Control Board

Electronic control