Shop replacement repair parts for Goodman Air Conditioner model GSX140181MA

Run cap 35/5mfd/440v/dual round

Blower motor 208-230v1ph 1/8hp 1050 rpm
Maintain your GSX140181MA central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The GSX140181MA is a one-and-a-half-ton, 14 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The GSX14 designation identifies Goodman’s 14 SEER R-410A residential outdoor condensing unit series. The 018 identifies one-and-a-half-ton capacity, the smallest standard residential tonnage in the GSX14 series. Goodman, Daikin, and Amana are related brands under the same parent company. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Goodman OEM parts for the GSX140181MA including the Goodman capacitor parts, Goodman contactor parts, Goodman fan motor parts, and Goodman high-pressure switch parts. Browse the Goodman central air conditioner parts catalog filtered by GSX140181MA for the complete parts inventory.
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the GSX140181MA. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
The GSX140181MA is a one-and-a-half-ton, 14 SEER R-410A residential outdoor condensing unit using R-410A Puron refrigerant. The GSX14 designation identifies Goodman’s 14 SEER R-410A residential outdoor condensing unit series. The 018 identifies one-and-a-half-ton capacity, the smallest standard residential tonnage in the GSX14 series. Goodman, Daikin, and Amana are related brands under the same parent company.
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
The GSX140181MA is a one-and-a-half-ton unit while the GSX140241FA is a two-ton unit on the Goodman GSX14 14 SEER R-410A platform. The dual run capacitor carries different compressor-section microfarad ratings between the two tonnages.
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.