Shop replacement repair parts for Kenmore Dryer model 110.77052600

Dryer gas burner valve solenoid set. If the dryer does not heat or heats intermittently the coils could be defective. To test, watch the burner and if the igniter glows for a while and then shuts off without the gas igniting, it usually means one of these coils is bad.

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Gas dryer sensor for igniter and flame. The sensor is located across from the gas igniter at the dryer’s burner assembly. This flame sensor should be closed for continuity at room temperature. Check for continuity with a multi-meter before replacing.

Dryer thermal fuse (or thermal limiter). This fuse is located on the exhaust duct. If the dryer overheats, the thermal fuse opens to cut off power to the dryer. The thermal fuse cannot be reset--if the thermal fuse is open, it must be replaced.

Thermal cutoff

High limit thermostat

Electronic control board assembly. NOTE: This part is often misdiagnosed and requires electrical testing with a volt/ohm meter to determine if it is defective.