Shop replacement repair parts for GE Dryer model DCVH660EH3MS


High-limit thermostat for dryer. L315-65. If the dryer overheats, this high-limit thermostat will cut off the power to the drive motor. If the high-limit thermostat has blown, the dryer won't start.

Dryer center outlet thermistor. *Note that it is not in the heating circuit so it likely will not be the cause of a dryer heating problem. It can however effect cycle times or cause a fault if defective. The resistence reading should read around 100 k ohms at room temperature.

Mica heater unit

Inlet control thermistor. Resistence reading should be around 100K ohms at room temperature and decrease with temperature rise.

The GE Appliances Backup Thermostat regulates heat in dryers if the control system fails. It replaces multiple part numbers and caution should be taken when servicing or repairing appliances. Consult the owner's manual for instructions and safety measures.

This is a Genuine Replacement Part. General Electric (GENF0) WE4M160 High Limit Thermostat.

Dryer heating element assembly. If the dryer won't heat, first check the thermal fuse to determine if has blown. If the thermal fuse has not blown, the heating element might be defective. The heating element will often have a break in the coil if it is defective.

Motor and pulley assembly

Main power control board assembly

Sensor harness