Shop replacement repair parts for Kenmore Dryer model 110.68072801

Dryer thermistor. This thermistor should read approximately 11.9K Ohms of resistance at 70 degrees Fahrenheit (21’ Celsius). If the thermistor is defective, it may prolong or shorten the drying time or cause a fault code. A defective thermistor is not responsible for a dryer not heating.

Dryer heating element. If the dryer no longer heats then the heating element may have failed, but it is not the most common cause. The most common cause for a dryer to stop heating is a blown thermal fuse.

Thermal cut out fuse and high limit thermostat kit

Dryer thermal fuse (or thermal limiter). This fuse is located on the exhaust duct. If the dryer overheats, the thermal fuse opens to cut off power to the dryer. The thermal fuse cannot be reset--if the thermal fuse is open, it must be replaced.

Hi-limit thermostat & thermistor assembly on heating element housing, L295-80F Thermistor should read around 50 to 60Kohms at room temperature.

Dryer drum drive motor

Cntrl-elec

Cntrl-elec

Wire harness

Harns-wire