Video & Articles: Appliance & Equipment RepairRheem Furnace Not Heating? Furnace Flame Sensor #62-23543-01

Rheem Furnace Not Heating? Furnace Flame Sensor #62-23543-01

01:35
Furnace not igniting or heating? This video provides step-by-step instructions for replacing the flame sensor on Rheem furnaces. The most common reason for replacing the flame sensor is if the furnace won't heat and testing the sensor proves it is at fault.

All of the information in this flame sensor replacement video is applicable to the following brands: Rheem, Ruud, DuroGuard, WeatherKing, Thermal Zone

Step By Step Instructions

1
To replace the flame sensor in your furnace first turn off the power to the furnace.
2
Slide the upper access panel up to detach.
3
Use a long flat-head screwdriver to unthread the mounting screw securing the flame sensor.
4
Pull out the old sensor and disconnect the wire.
5
Install the new flame sensor by first connecting the wire.
6
Carefully position the new sensor on the burner bracket.
7
Rethread the mounting screw to secure.
8
Replace the upper access panel.
9
With the repair completed, turn the power back on and your furnace should be ready for use.
Description
Furnace not igniting or heating? This video provides step-by-step instructions for replacing the flame sensor on Rheem furnaces. The most common reason for replacing the flame sensor is if the furnace won't heat and testing the sensor proves it is at fault.

All of the information in this flame sensor replacement video is applicable to the following brands: Rheem, Ruud, DuroGuard, WeatherKing, Thermal Zone
Step-By-Step Instructions
1
To replace the flame sensor in your furnace first turn off the power to the furnace.
2
Slide the upper access panel up to detach.
3
Use a long flat-head screwdriver to unthread the mounting screw securing the flame sensor.
4
Pull out the old sensor and disconnect the wire.
5
Install the new flame sensor by first connecting the wire.
6
Carefully position the new sensor on the burner bracket.
7
Rethread the mounting screw to secure.
8
Replace the upper access panel.
9
With the repair completed, turn the power back on and your furnace should be ready for use.

Applicable Product Model

Parts Needed
Total$0.00

Related Articles & Videos

02:03
Part Replacement
Rheem Furnace Not Heating? Igniter Replacement #62-24164-01
01:53
Part Replacement
Rheem Furnace Safety Limit Switch Replacement #47-25349-01
03:04
Part Replacement
Rheem Furnace Starts/Stops? Draft Inducer Motor #70-101087-81
01:54
Part Replacement
Rheem Furnace Pressure Switch Replacement #42-101225-81
03:44
Part Replacement
Rheem Furnace Not Heating? Replace Gas Valve #60-100394-03