Video & Articles: Appliance & Equipment RepairPayne Furnace Run Capacitor Replacement #P291-1003

Payne Furnace Run Capacitor Replacement #P291-1003

02:09
This video provides step-by-step repair instructions for replacing the run capacitor on a Payne furnace. The most common reason for replacing the run capacitor is when the furnace fan isn’t working.

All of the information for this run capacitor replacement video is applicable to the following brands:
Payne

Step By Step Instructions

1
Before you replace the run capacitor in your furnace first turn off the power to the furnace.
2
Use a flat-head screwdriver to unthread the screws securing the lower access panel and remove the panel.
3
To ensure the run capacitor is discharged, place a screwdriver with an insulated handle across the terminals – avoid touching the screwdriver blade.
4
Now remove the screw to release the capacitor mounting bracket.
5
Disconnect the wires to fully remove the old component.
6
Install the new run capacitor by first connecting the wires to the terminals.
7
Insert the bracket tab into the slot in the blower housing align the capacitor in the bracket then thread the screw to secure.
8
Realign the lower access panel and rethread the screws.
9
With the repair completed, turn the power supply back on and your furnace should be ready for use.
Description
This video provides step-by-step repair instructions for replacing the run capacitor on a Payne furnace. The most common reason for replacing the run capacitor is when the furnace fan isn’t working.

All of the information for this run capacitor replacement video is applicable to the following brands:
Payne
Step-By-Step Instructions
1
Before you replace the run capacitor in your furnace first turn off the power to the furnace.
2
Use a flat-head screwdriver to unthread the screws securing the lower access panel and remove the panel.
3
To ensure the run capacitor is discharged, place a screwdriver with an insulated handle across the terminals – avoid touching the screwdriver blade.
4
Now remove the screw to release the capacitor mounting bracket.
5
Disconnect the wires to fully remove the old component.
6
Install the new run capacitor by first connecting the wires to the terminals.
7
Insert the bracket tab into the slot in the blower housing align the capacitor in the bracket then thread the screw to secure.
8
Realign the lower access panel and rethread the screws.
9
With the repair completed, turn the power supply back on and your furnace should be ready for use.

Applicable Product Model

icons/furnace
Brand
Product Type
Model
Subtype
Parts Needed
Total$0.00

Related Articles & Videos

10:39
Part Replacement
Payne Furnace Replace Universal Blower Motor #10587
02:00
Part Replacement
Payne Furnace Limit Switch Replacement #HH680351
09:11
Part Replacement
Payne Furnace Blower Motor Replacement #HC43AE134
02:49
Part Replacement
Payne Furnace Won't Work? Replace Control Board #HK42FZ018
05:08
Part Replacement
Payne Furnace Gas Valve Replacement #EF32CB192