If your Haier air conditioner is short cycling, the unit starts and stops too often instead of running long enough to cool the room properly. This kind of air conditioner short cycling is usually tied to a control problem, with the control board being the most likely cause because it regulates voltage to the unit’s major components. The main control board can cause the same issue, followed by a faulty user control and display board that sends bad commands for fan speed or cooling temperature. If the AC turns on and off quickly, also check the thermistor and temperature sensor, since either one can misread room temperature and tell the control board to shut the system down too soon. A temperature control thermostat can also make a Haier air conditioner keep cycling if it fails to maintain the proper compressor delay. Use a multimeter where needed and compare readings to your owner’s manual. Enter your model number on RepairClinic.com to find the exact control board, thermistor, sensor, thermostat, or display board for your specific Haier air conditioner.

01 - Haier Air Conditioner Control Board

The control board regulates the voltage to all of the air conditioner components. If the control board fails, the air conditioner may short cycle. Control boards are often misdiagnosed; make sure to check more commonly defective parts first before replacing the control board.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Haier Air Conditioner Main Control Board

The main control board regulates the voltage to all of the air conditioner components. If the control board fails, the air conditioner may short cycle. Control boards are often misdiagnosed; make sure to check more commonly defective parts first before replacing the main control board.
Highly Likely

03 - Haier Air Conditioner User Control and Display Board

The user control and display board allows the user to operate the unit by selecting fan speeds and cooling temperatures. If the board is defective, the air conditioner may short cycle. If the temperature sensor or thermistor tests appropriately with a multimeter, it's possible the user control and display board is malfunctioning and will need to be replaced.
Highly Likely

04 - Haier Air Conditioner Thermistor

The thermistor is a sensor connected to the control board that detects the temperature of the air. The resistance value of the thermistor changes in conjunction with the air temperature. If the air temperature rises, the resistance value will decrease. A malfunctioning thermistor may cause the air conditioner to short cycle. To determine if the thermistor is at fault, use a multimeter to test it for continuity. If the thermistor does not have continuity, or if the resistance of the thermistor does not change with a change in temperature, replace the thermistor. (To find specific temperature and resistance values, try check...ing your user’s manual.)
Common

05 - Haier Air Conditioner Temperature Sensor

The temperature sensor is connected to the control board and detects the temperature of the air. The resistance value of the sensor changes in conjunction with the air temperature. If the air temperature rises, the resistance value will decrease. A malfunctioning temperature sensor may cause the air conditioner to short cycle. To determine if the sensor is at fault, use a multimeter to test it for continuity. If the sensor does not have continuity, or if the resistance of the sensor does not change with a change in temperature, replace the component. (To find specific temperature and resistance values, try checking your us...er’s manual.)
Common

06 - Haier Air Conditioner Temperature Control Thermostat

The temperature control thermostat is a sensor which monitors the temperature of the air and activates a switch to provide power to the fan and compressor when the air temperature drops below a set point. If the thermostat isn’t working, the air conditioner may short cycle. When the thermostat shuts the compressor off there needs to be approximately a five to ten minute delay to let the refrigerant equalize before the compressor will start again. If the refrigerant has not had time to equalize the compressor may not start. If the thermostat is short cycling it will need to be replaced. To determine if the temperature contr...ol thermostat is defective, use a multimeter to test it for continuity. If the thermostat does not have continuity, replace it. (Note: Some thermostats may also control a heater and, as a result, will have three terminals. Refer to your air conditioner’s wiring diagram for more information.)
Common

Frequently Asked Questions

Why is my Haier air conditioner short cycling?
How do I test a Haier AC thermistor or temperature sensor?
Can a bad temperature control thermostat make a Haier window AC short cycle?
Should I replace the control board if my Haier air conditioner keeps cycling?
How do I find the right Haier air conditioner part for a short cycling repair?