Choose Product
Identify Problem
03
Find Solutions

Hotpoint Air Conditioner is short cycling

If your Hotpoint air conditioner is short cycling, the unit is shutting off and starting back up too quickly instead of completing a normal cooling cycle. This can feel like the AC turns on and off quickly, the air conditioner keeps cycling, or a window AC short cycling problem. The most likely cause is a faulty control board, which regulates voltage to the air conditioner’s components. A bad main control board can cause the same symptom and is also a common misdiagnosis, so check related sensors first when possible. The user control and display board may also be at fault if it is not correctly processing fan speed or temperature settings. From there, test the thermistor and temperature sensor, since either one can send the wrong air temperature reading to the board. A failing temperature control thermostat can also short cycle the compressor, especially if it does not allow enough delay for refrigerant pressure to equalize. Enter your Hotpoint model number on RepairClinic.com to find the exact replacement part for your specific air conditioner.

01 - Hotpoint Air Conditioner Control Board

The control board regulates the voltage to all of the air conditioner components. If the control board fails, the air conditioner may short cycle. Control boards are often misdiagnosed; make sure to check more commonly defective parts first before replacing the control board.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Hotpoint Air Conditioner Main Control Board

The main control board regulates the voltage to all of the air conditioner components. If the control board fails, the air conditioner may short cycle. Control boards are often misdiagnosed; make sure to check more commonly defective parts first before replacing the main control board.
Highly Likely

03 - Hotpoint Air Conditioner User Control and Display Board

The user control and display board allows the user to operate the unit by selecting fan speeds and cooling temperatures. If the board is defective, the air conditioner may short cycle. If the temperature sensor or thermistor tests appropriately with a multimeter, it's possible the user control and display board is malfunctioning and will need to be replaced.
Highly Likely

04 - Hotpoint Air Conditioner Thermistor

The thermistor is a sensor connected to the control board that detects the temperature of the air. The resistance value of the thermistor changes in conjunction with the air temperature. If the air temperature rises, the resistance value will decrease. A malfunctioning thermistor may cause the air conditioner to short cycle. To determine if the thermistor is at fault, use a multimeter to test it for continuity. If the thermistor does not have continuity, or if the resistance of the thermistor does not change with a change in temperature, replace the thermistor. (To find specific temperature and resistance values, try check...ing your user’s manual.)
Common

05 - Hotpoint Air Conditioner Temperature Sensor

The temperature sensor is connected to the control board and detects the temperature of the air. The resistance value of the sensor changes in conjunction with the air temperature. If the air temperature rises, the resistance value will decrease. A malfunctioning temperature sensor may cause the air conditioner to short cycle. To determine if the sensor is at fault, use a multimeter to test it for continuity. If the sensor does not have continuity, or if the resistance of the sensor does not change with a change in temperature, replace the component. (To find specific temperature and resistance values, try checking your us...er’s manual.)
Common

06 - Hotpoint Air Conditioner Temperature Control Thermostat

The temperature control thermostat is a sensor which monitors the temperature of the air and activates a switch to provide power to the fan and compressor when the air temperature drops below a set point. If the thermostat isn’t working, the air conditioner may short cycle. When the thermostat shuts the compressor off there needs to be approximately a five to ten minute delay to let the refrigerant equalize before the compressor will start again. If the refrigerant has not had time to equalize the compressor may not start. If the thermostat is short cycling it will need to be replaced. To determine if the temperature contr...ol thermostat is defective, use a multimeter to test it for continuity. If the thermostat does not have continuity, replace it. (Note: Some thermostats may also control a heater and, as a result, will have three terminals. Refer to your air conditioner’s wiring diagram for more information.)
Common

Frequently Asked Questions

Why is my Hotpoint air conditioner short cycling?
How do I test a Hotpoint AC thermistor or temperature sensor?
Can a bad temperature control thermostat make my AC turn on and off quickly?
Should I replace the control board if my Hotpoint air conditioner keeps cycling?
How do I find the right Hotpoint air conditioner part for a short cycling repair?

Shop by Hotpoint Air Conditioner Parts