Choose Product
Identify Problem
03
Find Solutions

Haier Air conditioner not blowing enough

If your Haier air conditioner is not blowing enough air, start with the parts that actually move air through the unit. The most likely problem is a failing condenser fan motor, especially if it is getting the correct voltage but will not run, or if its capacitor is bulging, leaking, or unable to hold a charge. Next, check the dual shaft fan motor, which turns both the rear condenser fan blade and the front fan blade that pushes cooled air into the room. A burned-out fan motor can also cause AC weak airflow or make a window air conditioner airflow weak even when the unit still powers on. If the motors test good, look for clogged or restricted coils, since dirty indoor or outdoor coils reduce airflow and make the unit run longer. A clogged, dirty, or damaged air filter can also block airflow over the evaporator coil, causing frost buildup and even less air movement. Enter your Haier model number on RepairClinic.com to find the exact condenser fan motor, dual shaft fan motor, fan motor, air filter, or other replacement part for your specific air conditioner.

01 - Haier Air Conditioner Condenser Fan Motor

To determine if the condenser fan motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage, but the motor still won’t run, you should inspect the capacitor, if applicable, for any bulging or leaking. You can also use a multimeter to determine if the capacitor can hold and release its charge. If the capacitor appears to be in good condition, replace the condenser fan motor.
Enter model number to search for the required part specific to your product
Common

02 - Haier Air Conditioner Dual Shaft Fan Motor

An air conditioner dual shaft fan motor is the component that spins both the condenser fan blade in the rear of the unit and the fan blade that forces the cooled air out the front vent. If the fan motor is burned out, the unit will not be able to blow enough air. You can use a multimeter to determine if power is reaching the fan motor. If power is reaching the motor, but it doesn't run, the component will need to be replaced.
Less Common

03 - Haier Air Conditioner Fan Motor

An air conditioner fan motor is the component that spins the fan blade or blower wheel to circulate the air. If one of the fan motors is burned out, the unit will not be able to blow enough air. You can use a multimeter to determine if power is reaching the fan motor. If power is reaching the motor, but it doesn't run, the component will need to be replaced.
Less Common

04 - Clogged or Restricted Coils

Both the indoor and outdoor coils need to be clear for the air conditioner to work efficiently. A clogged or restricted coil will reduce air flow causing the unit to run longer.
Less Common

05 - Haier Air Conditioner Air Filter

If the air filter is clogged, air cannot flow properly through the air conditioner. This greatly reduces the cooling capacity of the air conditioner. In addition, if the air filter is clogged, the evaporator coils will frost over. Most air filters used in stand-alone air conditioners can be cleaned with soap and water. Only filters that are extremely clogged with debris or damaged will need to be replaced.
Less Common

06 - Dirty or Damaged Air Filter

If the air filter becomes clogged with dirt, it restricts air flow over the evaporator coils. If the air flow is reduced, the evaporator coils get too cold, which then causes the humidity in the room to condense on the coils and freeze. As frost accumulates on the coils, the frost restricts the air flow even more. Eventually, the entire evaporator coil assembly will frost over, causing the air flow to be completely restricted. Most air filters used in stand-alone air conditioners can be cleaned with soap and water. Only filters that are extremely clogged with debris or damaged will need to be replaced.
Less Common

Frequently Asked Questions

Why is my Haier air conditioner not blowing enough air?
What should I check if my Haier window air conditioner airflow is weak?
Can a bad capacitor make my Haier AC fan not work?
Why is my Haier air conditioner freezing up and not blowing hard?
How do I find the right Haier air conditioner fan motor, capacitor, or air filter?

Shop by Haier Air Conditioner Parts