Bryant Air conditioner won't turn off

If your Bryant air conditioner won't turn off, start with the things that make the unit run longer than it should, then move into the electrical controls. Dirty condenser coils are the most likely cause because they can’t release heat properly, so the compressor keeps running while the system struggles to reach the set temperature. Next, check the temperature control thermostat and thermostat. If either one is shorted or not switching correctly, it can keep sending voltage to the fan motor and compressor, making the AC run continuously or leaving the air conditioner compressor running constantly. A dirty or damaged air filter can also reduce airflow and cooling capacity enough that the air conditioner keeps running. If those parts check out, test the thermistor, which reports room temperature to the control board, and consider the relay board only after more common failures have been ruled out. RepairClinic.com can help you match the right Bryant air conditioner part, including a thermostat, thermistor, air filter, or relay board. Enter your model number to find the exact replacement part for your specific air conditioner.

01 - Condenser Coils are Dirty

The condenser coils dissipate the heat as the refrigerant passes through the coils. If the condenser coils are dirty, they won’t be able to dissipate the heat as effectively. As debris builds up on the coils, the air conditioner will become less efficient, causing the air conditioner to work harder to cool down. If the coils are significantly dirty, the air conditioner will not be able to maintain the proper temperature, and the compressor will run continuously in an attempt to cool the room. Check the condenser coils to determine if they are dirty. Refer to owner's manual for cleaning instructions.
Top Solution

02 - Bryant Air Conditioner Temperature Control Thermostat

The temperature control thermostat provides voltage to the fan motor and compressor. If the thermostat has shorted out, it might send continuous voltage to the compressor and cause the compressor to run all the time. To determine if the thermostat is shorted out, use a multimeter to test it for continuity. If the thermostat has continuity all the time, this indicates that it is shorted out and should be replaced. (Note: Some thermostats may also control a heater and, as a result, will have three terminals. Refer to your air conditioner’s wiring diagram for more information.)
Enter model number to search for the required part specific to your product
Highly Likely

03 - Bryant Air Conditioner Thermostat

The thermostat monitors the temperature of the air. When the air temperature rises above a set point, the thermostat activates a switch to provide power to the fan and compressor. If the thermostat is defective, it may cause the compressor to run continuously. To determine if the thermostat is defective, set the air conditioner to cooling and then use a multimeter to test the thermostat for continuity. If the thermostat does not have continuity while the air conditioner is set to cooling, replace the thermostat. (Note: Some thermostats may also control a heater and, as a result, will have three terminals. Refer to your air... conditioner’s wiring diagram for more information.)
Highly Likely

04 - Dirty or Damaged Air Filter

A dirty air filter will greatly reduce the cooling capacity of the air conditioner, which may cause the unit to run longer than normal. Most air filters used in stand-alone air conditioners can be cleaned with soap and water. Only filters that are extremely clogged with debris or damaged will need to be replaced. Refer to owner's manual for guidance.
Common

05 - Bryant Air Conditioner Thermistor

The thermistor is a sensor which detects the room air temperature. It is connected to the control board. If the thermistor is defective it will not have continuity when it should. If this happens the compressor runs all the time.
Common

06 - Bryant Air Conditioner Relay Board

The relay board provides voltage to many of the air conditioner components, including the fan motor and compressor. If there is a problem with the relay board, it might provide continuous voltage to the compressor. However, this is almost never the case. Before you replace the relay board, make sure you check more commonly defective parts. If you are certain that all of the other components are working properly, replace the relay board.
Common

Frequently Asked Questions

Why won't my Bryant air conditioner turn off?
Can dirty condenser coils make my Bryant AC run continuously?
How do I test a Bryant air conditioner thermostat problem?
Can a bad thermistor cause my Bryant air conditioner compressor to keep running?
How do I find the right Bryant air conditioner replacement part?

Shop by Bryant Air Conditioner Parts