If your White-Westinghouse air conditioner won’t turn off, the unit is usually either struggling to satisfy the temperature setting or a control part is sending power when it should not. Start with the most likely cause: dirty condenser coils. When the coils can’t release heat, the AC runs continuously and the compressor may keep running in an effort to cool the room. Next, check the temperature control thermostat and thermostat, since a shorted or defective thermostat can send constant voltage to the fan motor or compressor. A dirty or damaged air filter can also reduce airflow enough that the air conditioner keeps running longer than normal. Less commonly, a failed thermistor may misread room temperature and cause the air conditioner compressor to run constantly, or a faulty relay board may keep supplying voltage to the compressor. With a multimeter, your wiring diagram, and the right replacement part, this is a repair many DIYers can handle. Enter your model number on RepairClinic.com to find the exact White-Westinghouse air conditioner part that fits your unit.

01 - Condenser Coils are Dirty

The condenser coils dissipate the heat as the refrigerant passes through the coils. If the condenser coils are dirty, they won’t be able to dissipate the heat as effectively. As debris builds up on the coils, the air conditioner will become less efficient, causing the air conditioner to work harder to cool down. If the coils are significantly dirty, the air conditioner will not be able to maintain the proper temperature, and the compressor will run continuously in an attempt to cool the room. Check the condenser coils to determine if they are dirty. Refer to owner's manual for cleaning instructions.
Top Solution

02 - White-Westinghouse Air Conditioner Temperature Control Thermostat

The temperature control thermostat provides voltage to the fan motor and compressor. If the thermostat has shorted out, it might send continuous voltage to the compressor and cause the compressor to run all the time. To determine if the thermostat is shorted out, use a multimeter to test it for continuity. If the thermostat has continuity all the time, this indicates that it is shorted out and should be replaced. (Note: Some thermostats may also control a heater and, as a result, will have three terminals. Refer to your air conditioner’s wiring diagram for more information.)
Highly Likely

03 - White-Westinghouse Air Conditioner Thermostat

The thermostat monitors the temperature of the air. When the air temperature rises above a set point, the thermostat activates a switch to provide power to the fan and compressor. If the thermostat is defective, it may cause the compressor to run continuously. To determine if the thermostat is defective, set the air conditioner to cooling and then use a multimeter to test the thermostat for continuity. If the thermostat does not have continuity while the air conditioner is set to cooling, replace the thermostat. (Note: Some thermostats may also control a heater and, as a result, will have three terminals. Refer to your air... conditioner’s wiring diagram for more information.)
Highly Likely

04 - Dirty or Damaged Air Filter

A dirty air filter will greatly reduce the cooling capacity of the air conditioner, which may cause the unit to run longer than normal. Most air filters used in stand-alone air conditioners can be cleaned with soap and water. Only filters that are extremely clogged with debris or damaged will need to be replaced. Refer to owner's manual for guidance.
Common

05 - White-Westinghouse Air Conditioner Thermistor

The thermistor is a sensor which detects the room air temperature. It is connected to the control board. If the thermistor is defective it will not have continuity when it should. If this happens the compressor runs all the time.
Common

06 - White-Westinghouse Air Conditioner Relay Board

The relay board provides voltage to many of the air conditioner components, including the fan motor and compressor. If there is a problem with the relay board, it might provide continuous voltage to the compressor. However, this is almost never the case. Before you replace the relay board, make sure you check more commonly defective parts. If you are certain that all of the other components are working properly, replace the relay board.
Common

Frequently Asked Questions

Why won't my White-Westinghouse air conditioner turn off?
Why does my White-Westinghouse AC run continuously even when the room is cool?
Can a dirty air filter or condenser coils make an air conditioner compressor run constantly?
How do I test a White-Westinghouse air conditioner thermostat or thermistor?
How do I find the right White-Westinghouse air conditioner replacement part?