Choose Product
Identify Problem
03
Find Solutions

LG Air conditioner coils freezing

If your LG air conditioner coils are freezing, the problem is usually restricted airflow, and the air filter is the first place to check. A dirty or damaged air filter can block air across the evaporator coil, causing moisture to freeze and eventually choke off airflow completely. If the AC coils are frozen in only one section, a sealed system or refrigerant leak may be involved, which requires a licensed technician. A dirty evaporator coil can also lead to evaporator coil freezing, especially when combined with a clogged blower wheel or neglected filter. If airflow still seems weak, the LG dual shaft fan motor or fan motor may not be spinning the fan blade or blower wheel properly, which can make a window air conditioner freezing up problem worse and may also overheat the compressor. Clean what can be safely cleaned, replace damaged parts, and enter your model number on RepairClinic.com to find the exact LG air filter, fan motor, blower wheel, or other replacement part made for your specific air conditioner.

01 - Dirty or Damaged Air Filter

If the air filter becomes clogged with dirt, it restricts airflow over the evaporator coils. If the airflow is reduced, the evaporator coils get too cold, which then causes the humidity in the room to condense on the coils and freeze. As frost accumulates on the coils, the frost restricts the airflow even more. Eventually, the entire evaporator coil assembly will frost over, causing the airflow to be completely restricted. Most air filters used in stand-alone air conditioners can be cleaned with soap and water. Only filters that are extremely clogged with debris or damaged will need to be replaced.
Top Solution

02 - Sealed System Leak

If the air conditioner coils are freezing in only one area, there may be a sealed system (or refrigerant) leak. This is normally a very expensive repair. Repairs to the sealed system must only be performed by a licensed technician.
Top Solution

03 - Dirty Evaporator Coil

Proper air flow is critical for the air conditioner to work properly. The evaporator needs sufficient air flow to keep the condensing water from freezing. If the evaporator coil, air filter or blower wheel gets clogged, air flow will be reduced and ice can start forming on the evaporator coils, eventually freezing them up. It is recommended to replace the air filter routinely. Refer to owner's manual for air filter replacement frequency recommendations and for evaporator coil cleaning instructions.
Highly Likely

04 - LG Air Conditioner Dual Shaft Fan Motor

An air conditioner dual shaft fan motor is the component that spins the fan blade and blower wheel to both draw air into the unit and force it through the front vent and out the rear condenser coil. If the fan motor is burned out, the air won't be circulated which can cause the coils to freeze and the condenser and compressor to overheat. You can use a multimeter to determine if power is reaching the fan motor. If power is reaching the motor, but it doesn't run, the component will need to be replaced.
Enter model number to search for the required part specific to your product
Common

05 - LG Air Conditioner Air Filter

If the air filter is clogged, air cannot flow properly through the air conditioner. This greatly reduces the cooling capacity of the air conditioner. In addition, if the air filter is clogged, the evaporator coils will frost over. Most air filters used in stand-alone air conditioners can be cleaned with soap and water. Only filters that are extremely clogged with debris or damaged will need to be replaced.
Common

06 - LG Air Conditioner Fan Motor

An air conditioner fan motor is the component that spins the fan blade or blower wheel to circulate the air. If one of the fan motors is burned out, the air won't be circulated properly which can cause the coils to freeze. You can use a multimeter to determine if power is reaching the fan motor. If power is reaching the motor, but it doesn't run, the component will need to be replaced.
Common

Frequently Asked Questions

Why are my LG air conditioner coils freezing up?
Can a dirty air filter cause my LG window air conditioner to freeze up?
Why is my LG air conditioner not blowing enough air and freezing?
Can a bad fan motor make an LG AC coil freeze?
How do I find the right LG air conditioner air filter, fan motor, or blower part?

Shop by LG Air Conditioner Parts