Haier Central air conditioner won't turn on

If your Haier central air conditioner won't turn on, the most likely cause is a failed transformer, which supplies the 24-volt signal that tells the contactor to power the condensing unit. A defective furnace control board is the next possibility, especially if the contactor is not receiving 24 volts or the furnace blower motor has no power. If the thermostat display is blank, replace its batteries when applicable. Next, check for an incoming power problem, such as a tripped circuit breaker, blown fuse, or disconnect box switched off. A defective wall thermostat or thermostat wiring is less common but can prevent the cooling signal from reaching the contactor through the yellow thermostat wire. These checks can help diagnose an air conditioner not turning on, an AC unit not turning on, or an outside unit not turning on. Turn off power before opening equipment panels, and do not work on 240-volt wiring, the disconnect box, contactor, or other line-voltage components unless qualified. Use a licensed HVAC technician for electrical testing or repairs beyond basic battery and breaker checks. Enter your Haier model number to find the exact replacement transformer, control board, thermostat, or other part for your central air conditioner.

01 - Haier Central Air Conditioner Transformer

The furnace control board sends a low voltage signal of 24 volts to the thermostat. When the themostat cooling contacts close, a 24 volt signal is sent to the contactor coil, closing the high voltage circuit and sending power to the condensing unit components. Some furnaces have a separate transformer for the 24 volt circuit, so if the contactor is not receiving the proper voltage when the thermostat cooling contacts are closed, it's likely this transformer has failed and the component will need to be replaced.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Haier Central Air Conditioner Control Board

If the central air condensing unit contactor is not receiving 24 volts or power is not getting to the furnace blower motor, a possible cause is a defective furnace control board. While this is not a common problem, if all other potentially faulty components are working properly, the control board should be replaced.
Highly Likely

03 - Wall Thermostat Batteries

Most wall thermostats are either powered by an enclosed battery or by the furnace or air handler transformer. If the thermostat display is dead, you can remove the thermostat cover and look for replaceable batteries. Replace the batteries if needed and check operation.
Common

04 - Incoming Power Problem

Check to see if there is power to the furnace or air handler. One or more indicator lights on the control board should be illuminated. If there is no power to the furnace or air handler, check to see if a circuit breaker has tripped or a fuse has blown. Confirm the power switch on the side of the unit is turned on.
Common

05 - Haier Central Air Conditioner Wall Thermostat

The furnace control board sends a low voltage signal of 24 volts to the contactor through the wall thermostat. When the contactor receives the signal from the wall thermostat, it closes the circuit, sending voltage to the condensing unit components. There should be 24 volts between the common (“C”) and yellow (“Y”) thermostat wire terminals on the furnace control board when the wall thermostat is in the cooling mode. You can check for this voltage with a multimeter. If voltage is not reaching the contactor, it's likely the wall thermostat is defective and will need to be replaced.
Less Common

06 - Haier Central Air Conditioner Wifi Thermostat

The furnace control board sends a low voltage signal of 24 volts to the contactor through the WiFi thermostat. When the contactor receives the signal from the WiFi thermostat, it closes the circuit, sending voltage to the condensing unit components. There should be 24 volts between the common (“C”) and yellow (“Y”) thermostat wire terminals on the furnace control board when the WiFi thermostat is in the cooling mode. You can check for this voltage with a multimeter. If voltage is not reaching the contactor, it's likely the WiFi thermostat is defective and will need to be replaced.
Less Common

Frequently Asked Questions

Why won't my Haier central air conditioner turn on?
What should I check if my Haier AC has no power or the outdoor unit is not turning on?
How do I test the Haier thermostat or transformer when the AC won't start?
Could dead thermostat batteries keep my Haier central air conditioner from turning on?
How do I find the correct Haier replacement part for my central air conditioner?

Shop by Haier Central Air Conditioner Parts