Coleman Central air conditioner not blowing enough
If your Coleman central air conditioner is not blowing enough air, start with the most likely causes: a dirty evaporator coil, clogged air filter, or restricted blower wheel can reduce airflow and even cause the evaporator coil to freeze. Next, inspect the blower motor. A failing motor or seized bearings can leave your AC not blowing enough air through the vents; with power disconnected, the blower wheel should turn freely by hand. Check that every register is fully open, then inspect the blower wheel and housing for dust and debris that may be blocking airflow. If the filter, evaporator coil, and blower wheel are clean, the blower motor may be wired for the wrong speed, or ductwork may be leaking or undersized. This can cause weak airflow from AC vents throughout the home and may require an HVAC technician to verify system airflow. Turn off power before cleaning or servicing the blower assembly. Testing or replacing a blower motor involves electrical connections and may involve 240V line voltage, so use a qualified technician if you are not trained for that work. Enter your Coleman model number to find the exact blower motor, wheel, filter, or other replacement part for your central air conditioner.
01 - Dirty Evaporator Coil
Proper air flow is critical for the central air conditioner to work properly. The evaporator needs sufficient air flow to keep the condensing water from freezing. If the evaporator coil, air filter or blower wheel gets clogged, air flow will be reduced causing ice to start forming on the evaporator coils, eventually freezing them up. It is recommended to replace the air filter at least every 6 months or sooner depending on the conditions. Refer to owner's manual for air filter replacement frequency recommendations and for evaporator coil cleaning instructions.
Highly Likely
02 - Coleman Central Air Conditioner Blower Motor
Since the furnace's blower motor is the component that circulates the cooled air through the home's venting, a defective blower motor will result in the central air conditioner not blowing enough. You can use a multimeter to test the blower motor for electrical continuity, a continuous electrical path present in the motor, as well as determine if power is reaching the motor. You can also try turning the blower wheel by hand. If the wheel does not turn freely, it's likely the motor bearings have seized and the blower motor will need to be replaced.
Enter model number to search for the required part specific to your product
Some air registers have adjustable louvers that allow the air flow to be restricted or shut off entirely. This would be used to cut off the air flow to a room that isn't being used, or to restrict air flow to one room so more air will flow to the other rooms. If there is low air flow, check that the louvers are fully open.
Highly Likely
04 - Blower Motor Improperly Wired
Most central air conditioner blower motors have multiple speeds. Central air conditioners require higher speeds to move sufficent air throughout the home for cooling. If the blower was wired incorrectly it may not be moving enough air to properly cool the home. If the air filter and evaporator coil are clear and the air ducts are sealed properly but there is still not enough air flow, the blower may be wired incorrectly. Proper air flow is determined by several factors: the design of the duct work, the size of the home, and the size of the unit. A service technician may be required to determine if the air flow is sufficient for the home.
Highly Likely
05 - Coleman Central Air Conditioner Blower Wheel and Housing
Over time the blower wheel and housing can become clogged with dust and debris. This will restrict the air flow, preventing the central air system from blowing enough. You can try cleaning the blower wheel with compressed air or with a soft bristle brush. Use caution when trying to clean the blower wheel as the fins are sharp and can be easily damaged. If the blower is damaged it will need to be replaced.
Over time the blower wheel can become clogged with dust and debris. This will greatly affect the air flow circulating throughout the home. You can try cleaning the blower wheel with compressed air or with a soft bristle brush. Be sure to shut off power to the unit before attempting to clean the blower wheel. Use caution when trying to clean the blower wheel as the fins are sharp and can be easily damaged. If the blower is damaged it will need to be replaced.
Common
Frequently Asked Questions
Why is my Coleman central air conditioner not blowing enough air?
How do I troubleshoot a Coleman AC blower motor or blower wheel with weak airflow?
Can a dirty evaporator coil cause my air conditioner to blow weak air or freeze up?
Why is my central AC blower motor not moving enough air after a repair?
How do I find the correct Coleman central air conditioner blower motor or blower wheel part?