Heil Central air conditioner won't turn off

When your Heil central air conditioner won't turn off, a shorted contactor or a bad wall thermostat or thermostat wiring is the most likely cause, keeping a cooling signal on the yellow (Y) terminal even after the thermostat is set to Off. A shorted furnace control board or main control board can cause the same problem, though it is a less common cause, by continuing to send voltage to the outdoor condensing unit and making the air conditioner run constantly. A shorted board can continue sending voltage to the outdoor condensing unit, so the air conditioner keeps running even when the thermostat is set to Off. The main control board can cause the same problem and should be inspected for visible damage. Next, check the wall thermostat or thermostat wiring. A stuck contact between the common (C) and yellow (Y) thermostat wire terminals can keep the contactor energized and make the central air run continuously. If the thermostat shows continuity between C and Y while turned off, replace it. A shorted contactor is less common but can also keep the outdoor unit running after the control signal stops. Enter your model number to find the exact Heil replacement control board, thermostat, or contactor for your central air conditioner. Turn off power at the disconnect box and circuit breaker before inspecting components. Thermostat testing is low-voltage work, but the contactor and condensing unit contain dangerous 240-volt wiring. If you are not qualified to work around line voltage, have a licensed HVAC technician handle the diagnosis and repair.

01 - Heil Central Air Conditioner Control Board

If the furnace control board has a short, it may be providing continuous voltage to the central air condensing unit preventing it from turning off. Inspect the control board for any damage and replace if necessary.
Enter model number to search for the required part specific to your product
Common

02 - Heil Central Air Conditioner Main Control Board

If the furnace's main control board has a short, it may be providing continuous voltage to the central air condensing unit preventing it from turning off. Inspect the control board for any damage and replace if necessary.
Common

03 - Heil Central Air Conditioner Wall Thermostat

The wall thermostat has electrical contacts that send signal voltage back to the control board and the condensing unit's contactor to run the central air system. If the contact that controls the contactor sticks closed, it will send continuous voltage to the contactor, causing the central air system to run continuously. To determine if the thermostat is defective, use a multi-meter to test it for continuity. If the wall thermostat shows continuity between the common (“C”) and yellow (“Y”) thermostat wire terminals when the thermostat is in the off position, the thermostat has failed and will need to be replaced.
Common

04 - Heil Central Air Conditioner Wifi Thermostat

The WiFi thermostat has electrical contacts that send signal voltage back to the control board and the condensing unit's contactor to run the central air system. If the contact that controls the contactor sticks closed, it will send continuous voltage to the contactor, causing the central air system to run continuously. To determine if the thermostat is defective, use a multi-meter to test it for continuity. If the WiFi thermostat shows continuity between the common (“C”) and yellow (“Y”) thermostat wire terminals when the thermostat is in the off position, the thermostat has failed and will need to be replaced.
Common

05 - Heil Central Air Conditioner Contactor

The furnace control board sends a low voltage signal to the contactor. When the contactor receives the signal from the control board, it closes the circuit, sending voltage to the condensing unit components. If the contactor has shorted, it can send continuous voltage to the condensing unit's components resulting in the central air system not turning off. To determine if the contactor is at fault, use a multimeter to test the contactor for a short. If the contactor has shorted, replace it.
Less Common

Frequently Asked Questions

Why won't my Heil central air conditioner turn off?
How do I test a thermostat when my central air won't turn off?
How can I tell if the AC contactor is causing the system to run constantly?
Could the Heil furnace control board or main control board keep the air conditioner running?
How do I find the correct Heil central air conditioner replacement part?