Haier Central air conditioner - home's humidity is too high

If your Haier central air conditioner is not removing humidity, leaving the house humid with AC running, start with the air filter. A clogged Haier air filter restricts airflow, reduces cooling, and can cause the evaporator coil to frost over, preventing the air conditioner from dehumidifying properly. Check and replace the filter at least twice a year, or more often in dusty homes or homes with pets. Next, inspect the condenser coils. Dirty condenser coils cannot release heat efficiently, so the compressor may run continuously while the system still fails to lower humidity. Follow the owner's manual before cleaning the coils. If the filter and coils are clean, the temperature control thermostat may be shutting the system off too soon, shortening the cooling cycle and causing poor moisture removal. A faulty thermistor or control board can also send incorrect temperature information or incorrectly regulate the compressor and fan motor. Filter replacement and basic coil maintenance are generally DIY tasks, but testing electrical parts requires caution. Turn off power before servicing, and have a qualified technician handle line-voltage work, refrigerant, or any repair inside the sealed system. Enter your Haier model number to find the exact replacement air filter, thermostat, thermistor, or control board for your central air conditioner.

01 - Haier Central Air Conditioner Air Filter

If the air filter is clogged, air cannot flow properly through the air conditioner. This greatly reduces the cooling capacity of the air conditioner. In addition, if the air filter is clogged, the evaporator coils will frost over. Check and replace the air filter at least twice a year, more often in dusty/dirty environments or if there is a pet in the home.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Clogged Air Filter

If the air filter is clogged, air cannot flow properly through the home's venting system. This greatly reduces the cooling capacity of the air conditioner. In addition, if the air filter is clogged, the evaporator coils will frost over and not be able to remove moisture from the air. The air filter should be checked and replaced at least twice a year, more often in dusty/dirty environments. Refer to owner's manual for guidance.
Highly Likely

03 - Condenser Coils are Dirty

The condenser coils dissipate the heat as the refrigerant passes through the coils. If the condenser coils are dirty, they won’t be able to dissipate the heat as effectively. As debris builds up on the coils, the air conditioner will become less efficient, causing the air conditioner to work harder to cool down. If the coils are significantly dirty, the air conditioner will not be able to remove the moisture from the air and maintain the proper temperature, resulting in the compressor running continuously in an attempt to cool the room. Check the condenser coils to determine if they are dirty. Refer to owner's manual for cleaning instructions.
Highly Likely

04 - Haier Central Air Conditioner Temperature Control Thermostat

The temperature control thermostat is a sensor which monitors the temperature of the air and activates a switch to provide power to the fan and compressor when the air temperature drops below a set point. If the thermostat isn’t working properly, the air conditioner may not stay running long enough to remove the moisture in the air and cool properly. To determine if the temperature control thermostat is defective, use a multimeter to test it for continuity. If the thermostat does not have continuity, or is shutting off too soon, replace it. (Note: Some thermostats may also control a heater and, as a result, will have three... terminals. Refer to your air conditioner’s wiring diagram for more information.)
Common

05 - Haier Central Air Conditioner Thermistor

The thermistor is a sensor connected to the control board that detects the temperature of the air. The resistance value of the thermistor changes in conjunction with the air temperature. If the air temperature rises, the resistance value will decrease. To determine if the thermistor is at fault, use a multimeter to test it for continuity. If the thermistor does not have continuity, or if the resistance of the thermistor does not change with a change in temperature, replace the thermistor. (To find specific temperature and resistance values, try checking your user’s manual.)
Less Common

06 - Haier Central Air Conditioner Control Board

The main control board regulates the voltage to the compressor and the fan motor. If the control board fails, some components will not function properly or will not work at all. Control boards are often misdiagnosed; make sure to check more commonly defective parts first before replacing the control board.
Less Common

Frequently Asked Questions

Why is my Haier central air conditioner not removing humidity?
Can a clogged air filter cause my central air conditioner to blow warm air or freeze up?
How do I test the Haier air conditioner thermostat or thermistor?
What should I check if my central AC keeps running but the house is still humid?
How do I find the correct Haier central air conditioner replacement part?