Comfortmaker Central air conditioner - home's humidity is too high

When a Comfortmaker central air conditioner is not removing humidity, the most likely cause is a clogged air filter. A dirty filter restricts airflow, can cause the evaporator coil to frost over, and leaves your house humid with AC running. Check the Comfortmaker air filter first and replace it at least twice a year, or more often with pets, dust, or construction. Next, inspect the condenser coils for dirt and debris. Dirty condenser coils reduce heat transfer, make the compressor run longer, and can prevent the air conditioner from dehumidifying properly. If airflow and coil condition are good, a faulty temperature control thermostat may shut the system off too soon, while a defective thermistor can send inaccurate temperature readings to the control board. The control board is less common and should be tested only after the more likely causes are ruled out. Turn off power before inspecting parts, and leave any 240V electrical work to a qualified technician. Refrigerant or other sealed-system repairs require an EPA 608-certified HVAC technician. Enter your Comfortmaker model number to find the exact replacement air filter, thermostat, thermistor, or control board for your central air conditioner.

01 - Comfortmaker Central Air Conditioner Air Filter

If the air filter is clogged, air cannot flow properly through the air conditioner. This greatly reduces the cooling capacity of the air conditioner. In addition, if the air filter is clogged, the evaporator coils will frost over. Check and replace the air filter at least twice a year, more often in dusty/dirty environments or if there is a pet in the home.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Clogged Air Filter

If the air filter is clogged, air cannot flow properly through the home's venting system. This greatly reduces the cooling capacity of the air conditioner. In addition, if the air filter is clogged, the evaporator coils will frost over and not be able to remove moisture from the air. The air filter should be checked and replaced at least twice a year, more often in dusty/dirty environments. Refer to owner's manual for guidance.
Highly Likely

03 - Condenser Coils are Dirty

The condenser coils dissipate the heat as the refrigerant passes through the coils. If the condenser coils are dirty, they won’t be able to dissipate the heat as effectively. As debris builds up on the coils, the air conditioner will become less efficient, causing the air conditioner to work harder to cool down. If the coils are significantly dirty, the air conditioner will not be able to remove the moisture from the air and maintain the proper temperature, resulting in the compressor running continuously in an attempt to cool the room. Check the condenser coils to determine if they are dirty. Refer to owner's manual for cleaning instructions.
Highly Likely

04 - Comfortmaker Central Air Conditioner Temperature Control Thermostat

The temperature control thermostat is a sensor which monitors the temperature of the air and activates a switch to provide power to the fan and compressor when the air temperature drops below a set point. If the thermostat isn’t working properly, the air conditioner may not stay running long enough to remove the moisture in the air and cool properly. To determine if the temperature control thermostat is defective, use a multimeter to test it for continuity. If the thermostat does not have continuity, or is shutting off too soon, replace it. (Note: Some thermostats may also control a heater and, as a result, will have three... terminals. Refer to your air conditioner’s wiring diagram for more information.)
Common

05 - Comfortmaker Central Air Conditioner Thermistor

The thermistor is a sensor connected to the control board that detects the temperature of the air. The resistance value of the thermistor changes in conjunction with the air temperature. If the air temperature rises, the resistance value will decrease. To determine if the thermistor is at fault, use a multimeter to test it for continuity. If the thermistor does not have continuity, or if the resistance of the thermistor does not change with a change in temperature, replace the thermistor. (To find specific temperature and resistance values, try checking your user’s manual.)
Less Common

06 - Comfortmaker Central Air Conditioner Control Board

The main control board regulates the voltage to the compressor and the fan motor. If the control board fails, some components will not function properly or will not work at all. Control boards are often misdiagnosed; make sure to check more commonly defective parts first before replacing the control board.
Less Common

Frequently Asked Questions

Why is my Comfortmaker AC not removing humidity from the house?
Can a clogged air filter cause high humidity with the AC running?
How do dirty condenser coils cause my air conditioner to run constantly?
How do I test the thermostat or thermistor when my AC is not dehumidifying?
How do I find the correct Comfortmaker AC thermostat, thermistor, or filter part?