Tappan Central air conditioner has poor temperature control
When your Tappan central air conditioner has poor temperature control, check the air filter first. A clogged filter restricts airflow through the furnace or air handler, can cause the evaporator coil to frost over, and may leave your home with uneven cooling. Next, test the wall thermostat. Failed thermostat contacts can interrupt power to the furnace or air handler and condensing unit, causing an inaccurate AC temperature, intermittent operation, or an AC that is not holding temperature. Blocked or leaking vents can also reduce airflow and create hot or cold rooms. An oversized air conditioner may cool the home too quickly and shut off before air has time to circulate evenly. Replace a dirty air filter and inspect accessible vents yourself. Testing or replacing a thermostat involves low-voltage wiring, but shut off power before servicing; work inside the condensing unit or any 240-volt circuit should be handled by a qualified HVAC technician. Refrigerant and sealed-system repairs require EPA 608 certification. Enter your Tappan model number to find the exact air filter, thermostat, control board, blower motor, or other replacement part for your central air conditioner.
01 - Tappan Central Air Conditioner Air Filter
Check and replace the air filter at least twice a year, more often in dusty/dirty environments or if there is a pet in the home. A clogged air filter will greatly reduce the air flow of the furnace or air handler which can result in poor temperature control when trying to heat or cool the home.
Enter model number to search for the required part specific to your product
02 - Tappan Central Air Conditioner Wall Thermostat
The wall thermostat has electrical contacts that control the power supply to the furnace or air handler and condensing unit. If the contacts in the thermostat fail, certain components of the cooling system may not work or may only work intermittently. To determine if the thermostat is defective, use a multimeter to test it for continuity. If the wall thermostat does not show proper continuity, replace it.
03 - Tappan Central Air Conditioner Wifi Thermostat
The WiFi thermostat has electrical contacts that control the power supply to the furnace or air handler and condensing unit . If the contacts in the thermostat fail, certain components of the cooling system may not work or may only work intermittently. To determine if the thermostat is defective, use a multimeter to test it for continuity. If the WiFi thermostat does not show proper continuity, replace it.
If the air filter is clogged, air cannot flow properly through the home's venting system. This greatly reduces the cooling capacity of the air conditioner. In addition, if the air filter is clogged, the evaporator coils will frost over and not be able to remove moisture from the air. The air filter should be checked and replaced at least twice a year, more often in dusty/dirty environments. Refer to owner's manual for guidance.
Less Common
05 - Blocked or leaking vents
The furnace or air handler must have good airflow to work properly. A blocked or leaking vent can prevent good air flow and cause inconsistent room temperatures.
Less Common
06 - Oversized air conditioner
An oversized furnace or air handler will quickly heat or cool the home and shut off. This causes acceptable temperatures in certain areas but not in others. The circulated air needs time to distribute evenly throughout the home; the air recirculating through the furnace or air handler for longer periods of time will produce better results.
Less Common
Frequently Asked Questions
Why is my Tappan central air conditioner not holding temperature?
Why is my central AC not blowing enough air?
Can a thermostat cause poor temperature control or uneven cooling?
What should I do if my AC coil is freezing while the house is not cooling evenly?
How do I find the correct Tappan central air conditioner part for my repair?