Haier Central air conditioner circuit breaker keeps tripping

If your Haier central air conditioner circuit breaker keeps tripping, the outdoor condenser fan motor is the most likely cause. A shorted winding or seized motor can make the AC breaker trip repeatedly, so the condenser fan motor should be checked for free movement and electrical shorts. The next most likely cause is the furnace or air handler blower motor. A seized blower wheel, burnt motor, or shorted winding can overload the circuit. Less commonly, a shorted compressor, control board, or damaged wire harness may cause the central air tripping breaker problem. Turn off power at the disconnect box and circuit breaker before inspecting components. Testing or replacing parts in a 240V condensing unit or air handler is not safe for every DIYer, so have a qualified HVAC technician handle line-voltage diagnosis, compressor work, and any repair inside the sealed refrigerant system. Do not keep resetting a breaker that trips. Enter your Haier model number to find the exact replacement condenser fan motor, blower motor, compressor, control board, or wire harness for your specific air conditioner.

01 - Haier Central Air Conditioner Condenser Fan Motor

If the outdoor condensing unit's breaker or fuses keep tripping the condenser fan motor may be to blame. To determine if the condenser fan motor is shorted, use a multimeter to test the motor windings for a short to ground. If the condenser fan motor will not turn freely or the windings are shorted, replace the condenser fan motor.
Enter model number to search for the required part specific to your product
Common

02 - Haier Central Air Conditioner Fan Motor

If the outdoor condensing unit's breaker or fuses keep tripping the condenser fan motor may be to blame. To determine if the outdoor fan motor is shorted, use a multimeter to test the motor windings for a short to ground. If the outdoor fan motor will not turn freely or the windings are shorted, it will need to be replaced.
Common

03 - Haier Central Air Conditioner Blower Motor

Since the furnace or air handler's blower motor is the component that circulates the air through the home's venting, a defective blower motor may result in the circuit breaker tripping. You can try disconnecting the motor from the control board and see if the breaker still trips. You can also use a multimeter to test the blower motor for an electrical short, or see if there are any burnt smells coming from the motor. You can also try turning the blower wheel by hand. If the wheel does not turn freely, it's likely the motor bearings have seized. If the motor doesn't turn freely or is shorted the blower motor will need to b...e replaced.
Common

04 - Haier Central Air Conditioner Compressor

The compressor is located in the outdoor condensing unit and gets power through a service panel box next to the unit. If the compressor is shorted the fuses in the service panel box or the main breaker box may trip. You can test the compressor for shorts by using a multimeter. If the compressor windings are shorted the compressor itself or the whole unit will need to be replaced.
Less Common

05 - Haier Central Air Conditioner Control Board

The control board regulates the power supply to all of the components of the furnace or air handler. If the control board shorts out it can trip the circuit breaker. A shorted control board will usually have burn marks or smell burnt and will need to be replaced.
Less Common

06 - Haier Central Air Conditioner Wire Harness

A wire harness sends power and low voltage signals between the electrical components and the control board. If a wire harness becomes damaged, it can short out causing the circuit breaker to trip. Check the appropriate wire harnesses for breaks or loose connections. A damaged wire harness will need to be replaced.
Less Common

Frequently Asked Questions

Why does my Haier central air conditioner keep tripping the breaker?
What should I check first when the central air conditioner breaker keeps tripping?
Can a blower motor cause the air conditioner breaker to trip?
Could the compressor or control board be causing the breaker to trip?
How do I find the correct replacement part for my Haier central air conditioner?

Shop by Haier Central Air Conditioner Parts