Tappan Central air conditioner circuit breaker keeps tripping
If your Tappan central air conditioner keeps tripping the breaker, shut it off and do not repeatedly reset it. The most likely cause is a shorted condenser fan motor in the outdoor condensing unit. A seized motor or shorted windings can trip the air conditioner circuit breaker, so check whether the motor turns freely and have the windings tested for a short to ground. Next, inspect the outdoor fan motor, which may be listed separately from the condenser fan motor. A shorted blower motor, seized blower wheel, damaged control board, or burnt wiring can also cause the central air tripping breaker, especially at the furnace or air handler. Less commonly, a shorted compressor can make the AC condenser keep tripping the breaker, while a damaged wire harness may create an intermittent short. Turn off power at the disconnect box and circuit breaker before inspecting parts. Testing or replacing components in a 240V circuit is beyond safe DIY work unless you are qualified; hire a licensed HVAC technician for line-voltage diagnosis. Compressor or sealed-system repairs may require EPA 608 certification. Enter your model number to find the exact replacement condenser fan motor, blower motor, compressor, control board, or wire harness for your Tappan system.
01 - Tappan Central Air Conditioner Condenser Fan Motor
If the outdoor condensing unit's breaker or fuses keep tripping the condenser fan motor may be to blame. To determine if the condenser fan motor is shorted, use a multimeter to test the motor windings for a short to ground. If the condenser fan motor will not turn freely or the windings are shorted, replace the condenser fan motor.
Enter model number to search for the required part specific to your product
If the outdoor condensing unit's breaker or fuses keep tripping the condenser fan motor may be to blame. To determine if the outdoor fan motor is shorted, use a multimeter to test the motor windings for a short to ground. If the outdoor fan motor will not turn freely or the windings are shorted, it will need to be replaced.
Since the furnace or air handler's blower motor is the component that circulates the air through the home's venting, a defective blower motor may result in the circuit breaker tripping. You can try disconnecting the motor from the control board and see if the breaker still trips. You can also use a multimeter to test the blower motor for an electrical short, or see if there are any burnt smells coming from the motor. You can also try turning the blower wheel by hand. If the wheel does not turn freely, it's likely the motor bearings have seized. If the motor doesn't turn freely or is shorted the blower motor will need to b...e replaced.
The compressor is located in the outdoor condensing unit and gets power through a service panel box next to the unit. If the compressor is shorted the fuses in the service panel box or the main breaker box may trip. You can test the compressor for shorts by using a multimeter. If the compressor windings are shorted the compressor itself or the whole unit will need to be replaced.
The control board regulates the power supply to all of the components of the furnace or air handler. If the control board shorts out it can trip the circuit breaker. A shorted control board will usually have burn marks or smell burnt and will need to be replaced.
A wire harness sends power and low voltage signals between the electrical components and the control board. If a wire harness becomes damaged, it can short out causing the circuit breaker to trip. Check the appropriate wire harnesses for breaks or loose connections. A damaged wire harness will need to be replaced.